4./5. ATTACHING THE LOAD / HEIGHT ADJUSTMENT
ATTENTION!
- Do not underestimate the weight of the speaker.
- The attachment as well as the extension/retraction of the load should be
-
carried out by competent, i.e. technically and physically suitable personnel.
- Attentiveness and communication between the operators is essential.
- Always hold the extension tube with a firm grip
4.2
during the height adjustment.
-
Be prepared to tightenthe wing nut
4.6
immediately (e.g. should the load unintentionally slip)
We recommend that you first set the desired height,
secure it and then attach the load. If this is not possible,
a qualified person (P1) must hold the loaded extension
tube while another person (P2) handles the securing
elements safety hook
4.4
and wing nut
4.6
.
(in mm)
We recommend that you first remove the load and only then retract the extension tube. If this is not
possible, a qualified person (P1) must hold the loaded extension tube, while another person (P2) operates
the securing elements safety hook
5.5
and wing nut
5.6
.
4.1
Slightly loosen the wing nut of the tension
4.1
clamp
b.3
.
4.2
Lift the extension tube
b.4
, whereby…
4.3
…the safety hook automatically unlocks (and
4.3
remains in unlocked position).
4.4
The safety hook must be actively pushed into the
4.4
recess of the extension tube.
4.5
As soon as the hook is immersed, the tube is
4.5
lowered by 2 mm, thus preventing an untended
4.5
disengaging of the safety hook.
4.6
Retighten the wing nut.
CHECK, MAINTENANCE, CLEANING
5.1
Slightly loosen the wing nut of the tension
5.1
clamp
b.3
.
5.2
First lift the extension tube
b.4
a little…
5.3
…whereby the safety hook unlocks automatically.
5.4
Subsequently, retract the extension tube and…
5.5
…push the safety hook back into the recess and
5.5
let it hook into the extension tube.
5.6
Retighten the wing nut.
TECHNICAL DATA
FAULT-FINDING (F) and REPAIR (R)
Material
Base/floor plate: Cast iron, black powder coated
Tubes, safety hook: Steel black powder coated
Thread: Steel galvanised
Clamp, shells, caps: PA-6
Load-bearing capacity
max. 35 kg centric load
Dimensions
Base/floor plate: ø 450 mm, H = 21 mm
Tube combination: ø 42 / ø 35 mm
Height: min. 930 - max. 1430 mm (5 x 100 mm)
Cardboard
L x W x H: 1010 x 100 x 55 mm
Weight
net: 8.5 kg, gross: 9.1 kg
F: Stand wobbles:
F:
R: Check if floor is level.
F:
R: Check if base plate is level.
F:
R: Check tightness of the screws on the base tube
F:
r:
and tension clamp and retighten, if necessary.
F: Extension tube
b.4
retracts unintentionally:
F:
R: Press safety hook into recess and tighten wing nut (
4.4
-
4.6
).
F: Loudspeaker/monitor sits crooked:
F:
R: A small air gap between extension tube and mounting or flange adapter
F:
R:
is normal and necessary to prevent the speaker from wedging. This can
F:
R:
lead to a slightly crooked fit of the box.
F:
R: The installing of the levelling adapter 85890 fills the air gap.
F:
R: US boxes have a diameter of 38.1 mm (1 -1/2"). This deviation is
F:
R:
compensated by using the adapter sleeve 21326.
4. EXTENDING
6. DIMENSIONS
5. RETRACTION
- Careful handling of the extension tube maintains the telescoping, the load capacity
-
and safety of the installation.
- During maintenance work - always in unloaded condition - pay attention for possible
-
hazards (jamming, bumping, tipping over).
- For cleaning and maintenance, use a slightly damp cloth and a non-abrasive cleaning
-
agent.