24 OPERATION MANUAL
SERVICE AND MAINTENANCE
r
Turn the power breaker ON (Left on front below the
feed tray).
●
The RUN button lamp will go on.
• Do not press the RUN button.
t
Press the replenishment button (beaker) until the
READY lamp begins flashing (about 5 seconds).
●
It will take about 22 minutes for the tanks to be
filled.
As soon as the tanks are filled, the READY lamp
will stop flashing.
y
Fill the measuring cup exactly with 78
P
of starter
solution.
•Use the starter specified by the DEV solution.
u
Pour the starter solution into the starter solution
inlet in the developing tank.
i
Close the top cover.
RUN
READY
RUN
RUN
READY
RUN
™
Power Breaker
Press and hold
down for 5 seconds
™
Measuring Cup
™
Starter Solution
78
P
™
Starter Solution Inlet