Field Service
V
er. 1.0 Nov. 200
8
1
8
. Power supply errors
111
magicolor 1600W magicolor 1650EN
T
roubleshooting
1
8
. Power supply errors
18.1 Machine is not energized at all (PU operation check)
18.2 Control panel indicators do not light
Relevant electrical parts
Power switch
Printer control board (PRCB)
DC power supply (DCPU)
Step
Check Item
Location (Electrical
component)
Result
Action
1
Is the power source voltage being applied to
CN6 on DCPU?
1600W: L-3
1650EN: L-3
NO
Check wiring from
power outlet to
SW1 to CN1-N.
2
Are fuses (F1 and F2) on DCPU conduct-
ing?
⎯
NO
Change DCPU.
3
Are DC24
V
and DC5
V
being applied to
PJ17 on the printer control board?
1600W: E-5
1650EN: E-4 to 5
NO
Change DCPU.
YES
Change PRCB.
Relevant electrical parts
MFP board (MFPB)
Control panel
DC power supply (DCPU)
Step
Check Item
Location (Electrical
component)
Result
Action
1
Is the power source voltage being applied to
CN6 on DCPU?
1600W: L-3
1650EN: L-3
NO
Check wiring from
power outlet to
SW1 to CN1-N.
2
Are fuses (F1 and F2) on DCPU conduct-
ing?
⎯
NO
Change DCPU.
3
Is PJ1 on PRCB properly connected?
1600W: F to G-4 to 5
1650EN: F to G-3 to 4
NO
Reconnect.
For 1600W:
Is P105 on MFPB properly connected?
For 1650EN:
Is CN
8
on MFPB properly connected?
1600W: H-4 to 5
1650EN: F to G-3 to 4
For 1600W:
Is P102 on MFPB properly connected?
For 1650EN:
Is CN9 on MFPB properly connected?
1600W: I-6
1650EN: I-5
4
For magicolor 1600W
Is PJ1 on operation board properly con-
nected?
For magicolor 1650EN
Is CN1 on operation board properly con-
nected?
1600W: K-6
1650EN: K-5
NO
Reconnect.
YES
Operation panel.
Change MFPB.
Summary of Contents for magicolor 1600W
Page 3: ...ii Blank Page...
Page 28: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Main body magicolor 1600W magicolor 1650EN...
Page 174: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Lower Feeder Unit...
Page 179: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Lower Feeder Unit General Blank Page...
Page 193: ...4 Jam display Field Service Ver 1 0 Nov 2008 16 Lower Feeder Unit Troubleshooting Blank Page...
Page 194: ...SERVICE MANUAL 2008 11 Ver 1 0 FIELD SERVICE Duplex Option...
Page 199: ...1 Product specifications Field Service Ver 1 0 Nov 2008 2 Duplex Option General Blank Page...
Page 209: ...3 Other Field Service Ver 1 0 Nov 2008 12 Duplex Option Maintenance Blank Page...