FS-601 Field Service Ver2.0 Sep. 2004
How to use the adjustment section
3-1
III
Ad
ju
stmen
t/
S
et
ti
n
g
III Adjustment/Setting
1.
How to use the adjustment section
• “Adjustment/Setting” contains detailed information on the adjustment items and proce-
dures for this machine.
• Throughout this “Adjustment/Setting” the default settings are indicated by boldface.
A. Advance Checks
• Before attempting to solve the customer problem, the following advance checks must be
made.Check to see if:
1.
The power supply voltage meets the specifications.
2.
The power supply is properly grounded.
3.
The machine shares the power supply with any other machine that draws large current
intermittently (e.g., elevator and air conditioner that generate electric noise).
4.
The installation site is environmentally appropriate: high temperature, high humidity,
direct sunlight, ventilation, etc.; levelness of the installation site.
5.
The original has a problem that may cause a defective image.
6.
The density is properly selected.
7.
The Original Glass, slit glass, or related part is dirty.
8.
Correct paper is being used for printing.
9.
The units, parts, and supplies used for printing (developer, PC Drum, etc.) are properly
replenished and replaced when they reach the end of their useful service life.
10.
Toner is not running out.
B. Precautions for Service Jobs
1.
Be sure to unplug the power cord of the machine before starting the service job proce-
dures.
2.
If it is unavoidably necessary to service the machine with its power turned ON, use
utmost care not to be caught in the Scanner Cables or gears of the Exposure Unit.
3.
Special care should be used when handling the Fusing Unit which can be extremely
hot.
4.
The Developing Unit has a strong magnetic field. Keep watches and measuring instru-
ments away from it.
5.
Take care not to damage the PC Drum with a tool or similar device.
6.
Do not touch IC pins with bare hands.
2.
I/O check
2.1
Check procedure
• To allow sensors to be checked for operation easily and safely, data applied to the IC on
the board can be checked on the panel with the main unit in the standby state (including
a misfeed, malfunction, and closure failure condition).
<Procedure>
1.
Set the mode to the Tech. Rep. Mode.
2.
Touch the “State Confirm” Check key.
3.
Touch the “I/O Check” key.
Summary of Contents for FS-601
Page 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Page 2: ......
Page 4: ......
Page 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Page 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Page 38: ......
Page 40: ......
Page 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Page 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Page 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...