A High-Accuracy Benchtop Spectrophotometer

With Konica Minolta's Optical Technology

for High Performance

and Computer Control for Easy Operation

High-speed,

high-accuracy measurements

Measurements at

wavelengths from 360 to

740nm at 10nm pitch are taken in approximately
0.6 seconds. Konica Minolta's optical technology
ensures high absolute- value accuracy and
repeatability, and extremely strict quality control
provides higher inter-instrument agreement and
reliability.

q

Illumination/viewing geometry

meets ISO and

DIN standards for di:8

°

, de:8

°

(diffuse illumination/8

°

viewing angle) geometry and also conforms to CIE
and ASTM standards for d:0

°

(diffuse illumination/0

°

viewing angle) geometry.

w

Pulsed xenon lamp light source

provides high

stability, long life, and excellent repeatability on
dark and high-chroma colors.

e

6-inch integrating sphere

has a powdered

barium sulfate (BaSO

4

) coating with superior

optical characteristics.

r

Double-beam feedback system

monitors the

light emitted by the xenon lamp and automatically
compensates for changes in brightness or spectral
characteristics.

t

Flat holographic grating

efficiently separates

the light by wavelength to provide higher
repeatability for dark colors.

y

Silicon photodiode array sensor

quickly

converts the light separated by the grating to
electrical currents.

CM-3720d (Whiteness Model)/CM-3730d (Paper Industry Model)

UV cutoff filter switching (CM-3720d, CM-3730d)
Cuts off UV components having wavelengths of 420nm or less emitted by the light source. Useful for eliminating the effects
of fluorescence when measuring fluorescent materials having excitation wavelengths below 420nm.
Enables easy switching to normal measurement using illumination including ultraviolet radiation.
Low-illumination setting (CM-3720d, CM-3730d)
Reduces illumination level to one-fifth. Reduction of light quantity can eliminate triplet influences, which may occur
occasionally when measuring fluorescent materials at the normal illumination level.
Opacity jig (CM-3730d)
Enables easy switching of the background between white and black and ensures paper position does not shift during
opacity measurements.

Various measuring functions

u

Switchable between SCI and

SCE measurements

SCI (specular component included ) measurements
minimize the influence of surface conditions on
measured values, making it suitable for CCM
applications. SCE (specular component excluded)
measurements correspond closely to professional
visual evaluation.

i

Changeable measurement areas

Select measurement areas of 3

×

5mm,ø8mm, or

ø25.4mm according to the application.

o

Variable UV

The amount of UV included in the illumination can
be controlled in 1000 steps for measurements of
fluorescent materials.

!0

Transmittance measurements

The spectral transmittance of liquids or of specimens
in sheet or plate form can be measured using
di:0

°

, de:0

°

(diffuse illumination/0

°

viewing angle)

geometry.

Demands for higher accuracy and more analysis capabilities have been increasing,
particularly from R&D professionals. In response, Konica Minolta has utilized its long experience in optics and color measurement
to create the Spectrophotometer CM-3700d, a high-accuracy benchtop spectrophotometer suitable for not only research
and development, but also for quality control or CCM applications.

System Diagram

Personal computer

Accessory Case CM-A66

(standard accessory)

Spectrophotometer CM-3700d

Standard

accessories

Optional

accessories

Target Mask

CM-A91

(3x5mm)

Target Mask

CM-A93

( 25.4mm)

AC Adapter

RS-232C Cable CM-A52

(9-pin, 2m)

White Calibration Plate CM-A90

(with floppy disk containing calibration data)

Target Mask

CM-A92

( 8mm)

Cell

CM-A99

(20mm)

Cell

CM-A98

(10mm)

Cell

CM-A97

(2mm)

Plastic Cell

CM-A132

(20mm: set for 100)

Plastic Cell

CM-A131

(10mm: set for 100)

Plastic Cell

CM-A130

(2mm: set for 100)

Transmittance

Zero Calibration Plate

CM-A100

Transmittance Specimen Holder

CM-A96

Zero Calibration Box

CM-A94

Color Tiles

RS-232C Cables CM-A55

(9-pin, 5m)

u

o

!0

o

e

u

SCE

SCI

8

°

8

°

o

r

t

!0

w

q

y

Windows

®

is a trademark of Microsoft Corporation in the USA and other countries.

SpectraMagic

TM

NX

Supports Windows

®

2000/XP/Vista

(optional)

SpectraMagic

TM

NX

enables you to perform comprehensive color

inspection and analysis of incoming raw materials, in process production,

and outbound color critical goods and materials in virtually any industry.

With

SpectraMagic

TM

NX

you can insert digital images with measured data.

Measure samples in any of 8 universally accepted color spaces. Select

from 15 illuminants, and up to 40 indices to determine specific color and

appearance properties, such as strength, brightness, haze, yellowness,

opacity and strength. You can even configure up to 3 customized color

equations. Reports range from simple Pass/Fail to trend charts, histograms,

color plots, and spectral graphs.

SpectraMagic

TM

NX

comes with predefined

templates using skin technology, or you can create your own templates.

For illustrations and explanations to understanding color and color

measurement technology, there is a link to Konica Minolta's well known and

respected “Precise Color Communication”. Step by step navigation help.

SpectraMagic

TM

NX

CM-S100w