background image

For  correct  use  and  for  your  safety,  be  sure  to  read  the 
instruction manual before using the instrument.

Always connect the instrument to the specified 

power  supply  voltage.  Improper  connection 

may cause a fire or electric shock.

Be  sure  to  use  the  specified  batteries.  Using 

improper batteries may cause a fire or electric 

shock.

Certificate No : JQA-E-80027

Registration Date : March 12, 1997

Certificate No : YKA 0937154

Registration Date : March 3, 1995

System Diagram

Standard Accessories

*1 Operating temperature/humidity range of products for North America : 5 to 40˚C, relative humidity 80% or less (at 31˚C) with no condensation

Specifications

Optional Accessories

193

69

96

AA-size
battery (x4)

AC Adapter 

AC-A17

AC Adapter 

AC-A23 

(for Korea)

Vinyl cover
Dust cover

CM-A152

Target mask ø8mm

CM-A146

CM-2500d

RS232C cable

IF-A16

Hard case

CM-A148

Dust cover set

CM-A149

Zero calibration box

CM-A32

Personal Computer

(commercially available)

White calibration plate  

CM-A145

d/8 (diffuse illumination, 8-degree viewing ), equipped with simultaneous 
measurement of SCI (specular component included)/SCE(specular 
component excluded) Conforms to CIE No.15,ISO 7724/1,ASTM E1164,
DIN 5033 Teil7 and JIS Z8722 Condition C standard.
ø52mm
Silicon photodiode array (dual 40 elements)
Diffraction grating
360nm to 740nm
10nm
Approx. 10nm
0 to 175%, resolution: 0.01%
2 pulsed xenon lamps 
Approx. 1.5 seconds (approx. 2 seconds for fluorescent measurement)
3 seconds for SCI/SCE (4 seconds for fluorescent measurement)

Alkaline manganese:approx. 1000 measurements
MAV: ø8mm/ø11mm

Spectral Reflectance:Standard deviation within 0.1% (360 to 380nm within 0.2%)
Colorimetric Value : Standard deviation within 

E*ab 0.04(Measurement 

conditions:White calibration plate measured 30 times 
at 10-second intervals after white calibration was performed)
within 

E*ab 0.2 (MAV/SCI) Average for 12BCRA Series 

II 

color 

tiles compared to values measured with master body.
Single measurement/automatic averaging of multiple measurements 
(auto mode: 3, 5, 8 times/manual mode)
RS-232C standard
2/10 degrees (CIE 1931/2

°

,CIE 1964/10

°

)

A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation 
is possible using two light sources)
Spectral value/graph, colorimetric value, color difference value/graph, 
PASS/FAIL result
L*a*b*, L*C*h, CMC (1:1), CMC (2:1), CIE94, Hunter Lab, Yxy, Munsell, 
XYZ, MI, WI (ASTM E313), YI (ASTM E313/ASTM D1925), ISO Brightness 
(ISO 2470), Density status A/T, WI/Tint (CIE/Ganz), CIE00
1700 pieces of data (as SCI/SCE 1 data) * 700 pieces of data in the “ defined in COND.” mode.
* Total of the sample data for the COND and TASK modes and color difference target data
Tolerance for color difference (both box and eliptical tolerances can be set)
4 AA-size battery or AC adapter
69 x 96 x 193mm
Approx. 670g (without batteries)
5 to 40˚C, relative humidity 80% or less (at 35˚C) with no 
condensation
0 to 45˚C, relative humidity 80% or less (at 35˚C) with no 
condensation
White calibration plate, Target mask ø8mm, RS-232C cable, 
AC adapter, AA-size battery (x4)
Hard case, Dust cover set, Dust cover, 
SpectraMagic

TM

NX(software), Zero calibration box

Illumination/
viewing system

Sphere Size
Light-receiving element
Spectral separation device
Wavelength range 
Wavelength pitch 
Half bandwidth 
Reflectance range 
Light source 
Measurement time 
Minimum interval 
between measurements
Battery perfomance
Measurement/
illumination area
Repeatability

Inter instrument 
agreement 
Measurement 
mode
Interface
Observer
Illuminant

Display data

Color space/
colorimetric data

Data memory

Tolerance Display 
Power source
Size (WxHxD) 
Weight
Operating temperature/
humidity range (*1)
Storage temperature/
humidity range
Standard 
accessories 
Optional 
Accessories 

High  inter-instrument  agreement  between  the 
portable  CM-2500d  spectrophotometer  and  the 
desktop    CM-3000  series  make  it  easy  to  build  a 
total color control network.

R&D

Quality control

Production

CM-3700d

CM-3600d

Company

B

In-house color control

Color control among companies

R&D

Quality

Production

Company

A

R&D

Quality

Production

CM-2500d

CM-2500d

Dimensions 

(Units:mm) 

CM-2500d

Color control network by spectrophotometer

AGMGPK

Printed in Japan

9242-4879-41

2001  KONICA MINOLTA SENSING, INC.

SAFETY PRECAUTIONS

11

CM-S100w

SpectraMagic

TM 

NX

* The specifications and 

drawings given here are 
subject to change without 
prior notice.

Mac OS 10.3.7J   illustrator 10J
CM-2500d(E)_back.ai     2006.11.21

Reviews: