110-0007509/A
19
List of topside cables
Each topside cable used by the echo sounder system is listed.
Cable
Type
From
To
Minimum requirements
C1*
AC Power cable
Display
Vessel AC power
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C2*
AC Power cable
Power Supply Unit
Vessel AC power
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C4
Ground cable
Processor Unit
Vessel ground
1 x 6 mm
2
C5*
Video cable
Processor Unit
Display
This is a commercial cable.
C6
DC Power cable
Processor Unit
Vessel DC power
2 x 6 mm
2
C7
DC Power cable
Processor Unit
Power Supply Unit
2 x 6 mm
2
C8
Ethernet cable
Processor Unit
Sonar room
Cat 5e STP (Shielded Twis-
ted Pair)
C9
Ethernet cable
Processor Unit
Local Area
Network (LAN)
Cat 5e STP (Shielded Twis-
ted Pair)
C10
Serial cable
Processor Unit
External device(s)
2 x 4 x 0.5 mm
2
C16
Remote control
cable
Processor Unit
Remote control
box
2 x 0.25 mm
2
• Cables identified with an asterisk (*) are system or commercial cables. These cables
are provided in the delivery or with the relevant item.
• Cable numbers that are not used are spares for optional equipment and/or future
expansions.
• For more information about the cables, see:
Comments
.
Related topics
Cable layout and interconnections, page 15
Topside cable plan, page 17
Comments, page 20
Cable drawings and specifications, page 26