100
394149/D
Installing the Wide Band Transceiver (WBT) cables
The Wide Band Transceiver (WBT) cables include those used to connect the EK80 units
to AC mains power, as well as the control cables between the units. One high capacity
Ethernet cable connects the Wide Band Transceiver (WBT) to the topside Processor Unit.
Procedure
1
Connect the power cables.
If a WBT Cabinet is used:
a
Connect the power cable from the WBT Cabinet to the AC power outlet. (C21)
b
Verify that each Wide Band Transceiver (WBT) is connected to the power
distributor at the bottom of the cabinet.
If a WBT Cabinet is
not
used:
a
Connect the power cable from each Power Supply Unit to the relevant Wide
Band Transceiver (WBT). (C16)
b
Connect the power cable from each Power Supply Unit to the AC power
outlets. (C17)
Standard commercial AC mains cables are used. Each cable is supplied with the
relevant unit. The typical cable length is between 1,5 and 2 meters. If this is too
short you must use an extension cable (not recommended), mount a new power
outlet within range, or make your own power cable with sufficient length.
For more information, see the cable details:
•
AC power cable using IEC C13 inline socket, page 137
2
Connect the ground cables.
If a WBT Cabinet is used:
a
Verify that ground strap from the WBT Cabinet to vessel ground is secured.
b
Verify that each Wide Band Transceiver (WBT) is grounded inside the WBT
Cabinet.
If a WBT Cabinet is
not
used:
a
Connect the ground cable from each Wide Band Transceiver (WBT) to vessel
ground. (C15)
This cable must be provided by the installation shipyard. For more information,
see the cable details:
•
3
If you wish to use the synchronization method offered by the
Auxiliary
socket on
the Wide Band Transceiver (WBT), make the necessary connection. (C18)
For more information, see the cable details:
•
Synchronization using the Auxiliary socket on the transceiver, page 129
•
Auxiliary connector for synchronization, page 153
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...