System units
This chapter describes the installation of the EM 122 Transceiver Unit in the equipment
or operation room, and the Operator Station in the operation room.
The Remote Control Junction Box installation for a 0.5 degree system is also described.
Drawings showing the system and the physical dimensions are included in the text.
Topics
•
on page 41
•
on page 43
•
on page 47
•
on page 53
•
on page 56
Drawings showing the physical dimensions are included in the text.
Note
KM strongly recommends that an Uninterruptible Power Supply (UPS) is used to power
the Operator Station.
Operator station
Description
The EM 122 Operator Station consists of a Kongsberg PC based workstation. Main
units are computer chassis, display monitor, keyboard, mouse and units for external
data storage.
Location
It is recommended to place the Operator Station in a room with environmental conditions
similar to those required for extended human occupation. The Operator Station is usually
mounted in the operation room, in a rack.
317669/B
41
Summary of Contents for EM 122
Page 1: ...EM 122 Multibeam echo sounder Installation Manual...
Page 2: ......
Page 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Page 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Page 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Page 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Page 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Page 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Page 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Page 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Page 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Page 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Page 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Page 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Page 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Page 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Page 154: ...2013 Kongsberg Maritime...