16
436538/A
When 6-8 are linked, the transponder is ON.
With no connection between 6-8, the transponder is OFF.
3
Make sure that the external power supply 24 VDC is between 20 and 28 VDC.
4
Check the responder trigger signal.
5
Switch ON the unit by inserting the external power/responder cable.
Further requirements
It is recommended to test the transponder with the Test and Configuration unit (TTC) to
make sure the transponder is working properly before operation.
Changing between responder and
transponder mode
The transponder can also be used as a responder unit.
Prerequisites
The transponder must be charged before use.
Procedure
1
By default when the cNODE MiniS 1.11-50V Ti is turned on it is in transponder
mode.
2
When responder trigger signals are received, the mode is automatically changed
to responder.
3
Once the responder trigger signals stop, it will take 1 minute before the cNODE
MiniS 1.11-50V Ti changes automatically back to transponder mode.
Pre-deployment checks
Before deploying the transponder, it is important to do the following checks to make
sure the operation goes smoothly.
Context
It is recommended to test the transponder with the Test and Configuration unit (TTC) to
make sure the transponder is working properly before operation.
Procedure
1
Make sure the retaining cord is in place.
cNODE MiniS 1.11-50V Ti Instruction Manual