390755/G
7
Important
Working in an explosive atmosphere, there are some things you must be aware of.
WARNING
Explosion proof cNODE transponders do not have the same batteries as other
cNODE Maxi transponders and can not be interchanged.
The batteries must never be changed in an explosive environment.
Read the lithium batteries safety procedure before handling batteries.
System description
These transponders are designed to be used in an explosive atmosphere.
The transponders complies with the following directive:
• ATEX Directive – 2014/34/EU
The transponders complies with the following standards:
• IEC 60079-0:2017, 7th Edition, EN IEC 60079-0:2018, Explosive atmospheres - Part
0: Equipment - General requirements
• IEC 60079-1:2014, 7th Edition, EN 60079-1:2014, Explosive atmospheres - Part 1:
Equipment protection by flameproof enclosures "d"
• IEC 60086-1:2015, Primary batteries - Part 1: General
The transducer and end cap are made of titanium. The tube and all fasteners are made
of Super Duplex stainless steel.
The bottom end cap is engraved with information about the safety standards.
Summary of Contents for cNODE Maxi 31 Ex d
Page 1: ...390755 G May 2022 Kongsberg Maritime AS cNODE Maxi 31 Ex d Transponder Instruction Manual ...
Page 32: ...32 390755 G cNODE Maxi 31 80V 90 Exd Outline dimensions cNODE Maxi 31 Ex d Instruction Manual ...
Page 33: ...390755 G 33 cNODE Maxi 31 80V Exd Outline dimensions Drawings ...
Page 49: ......
Page 50: ... 2022 Kongsberg Maritime ...