38
390755/G
SECTION 6: Accidental release measures
During normal operation, accidental release measures are not applicable. Extreme
mechanical abuse to the battery may result in a ruptured seal and exposure.
As an immediate precautionary measure, isolate the spill or leak area at least 25 metres
(75 feet) in all directions. Keep unauthorized personnel away. Stay upwind, and keep out
of low areas. Ventilate closed areas before entering. Wear adequate personal protective
equipment.
Prevent material from contaminating soil and from entering sewers or waterways. Stop
the leak if safe to do so. Contain the spilled liquid with dry sand or earth. Clean up the
spills immediately.
Absorb spilled material with an inert absorbent (dry sand or earth). Scoop contaminated
absorbent into an acceptable waste container. Collect all contaminated absorbent and
dispose of it according to relevant regulations. Scrub the area with detergent and water;
collect all contaminated water for proper disposal.
SECTION 7: Handling and storage
Do not open, disassemble, crush or burn the battery.
1
Do not expose the battery to water, sea water or other high-conductivity liquids.
2
Avoid mechanical or electrical abuse.
3
Do not expose the battery to temperatures outside the range of -40 °C to +80 °C.
4
Store in a dry location.
Recommended relative air humidity is 40 to 70 %. To minimize any adverse affects
on the battery performance it is recommended that it is kept at room temperature
(25 °C ± 5 °C). Higher temperatures can result in shortened life.
5
Do not store the battery in direct sunlight.
6
Keep the battery out of reach of children.
The storage room must be properly ventilated. It must be provided with sturdy racks
with dedicated cradles for the batteries, and allow for easy removal of batteries in case of
fire. The room must be designated and clearly identified as a storage area, and entrance
should be restricted. The room must not be used as a general rest or work area.
Note
The storage room must have a sprinkler system or a fire station. A suitable fire hose (with
water) must be placed outside or in the proximity of the room.
cNODE Maxi 31 Ex d Instruction Manual
Summary of Contents for cNODE Maxi 31 Ex d
Page 1: ...390755 G May 2022 Kongsberg Maritime AS cNODE Maxi 31 Ex d Transponder Instruction Manual ...
Page 32: ...32 390755 G cNODE Maxi 31 80V 90 Exd Outline dimensions cNODE Maxi 31 Ex d Instruction Manual ...
Page 33: ...390755 G 33 cNODE Maxi 31 80V Exd Outline dimensions Drawings ...
Page 49: ......
Page 50: ... 2022 Kongsberg Maritime ...