This section contains the following topics:
Shutting down the operator terminal................................................................................80
Restarting the operator terminal.......................................................................................81
Upgrading the operator terminal software .......................................................................82
Upgrading the controller PS software..............................................................................82
Shutting down the operator terminal
Prior to switching off the system you should always ensure that the operator terminal
has been shut down in a controlled manner using the
Shut Down this Operator Terminal
function (see
Software Upgrade and Restart input dialog
on page 59).
Caution
Before attempting to shut down an operator terminal you must ensure that
the operator terminal is in Standby mode and does not have control of the
vessel's propulsion system.
To shut down the operator terminal in a controlled manner, proceed as follows:
1
Display the Software Upgrade and Restart input dialog.
2
Move the focus to the
Shut Down this Operator Terminal
field and change the option
to
Yes
.
3
Press the
Enter
button.
• The operator pop-up message
The Operator Terminal software will be Shut Down..
is displayed.
• The application software is shut down.
• When the application software has been shut down, the Microsoft Windows
message
System Shutdown
is displayed.
• After a few seconds the operating system is shut down.
• When the operating system has been shut down the audible signal horn sounds.
4
Press the
Silence/ack.
button.
• The audible signal is silenced.
80