Door Control Board: Board 1Ø4
®
for PM/SSC
Product Instruction
© 2000 KONE Inc.
61111-149
All rights reserved.
14
(R3) 2000-08-31
SET MICROSWITCH CAMS
PM/SSC door operator microswitch cams determine
where changes in door speed occur. Factory
settings are approximate. Set microswitch cams, if
necessary, per individual job requirements.
CL
CAM actuates CL microswitch when doors
are in their desired fully closed position.
PL
Initial opening CAM drops microswitch
when car door clutch has just engaged
both hoistway door rollers, but should not
drop microswitch if door interlock hangs
up.
OSDL
CAM drops OSDL microswitch when
doors are approximately half open.
CSDL
CAM drops CSDL microswitch when doors
are approximately 4 inches [10.2 mm] from
their fully closed position.
OL
CAM actuates OL microswitch when doors
are in fully open position.
DSD
(optional) CAM actuates DSD microswitch
when doors are approximately 4 to 6 inches
[10.2 to 15.2 mm] from fully closed position
when used with load balancing. CAM can
also be set for other customer
requirements.
F615-009 (2/97)