Komshine KPM-11M User Manual Download Page 2

Product description

7

Product features

8

     

Accurate measurement, error less than 0.2dB 
60 hours continuous use (only in optical power meter mode)

7 wavelengths (850/980/1300/1310/1490/1550/1625) nm

Back clip design, mini compact

Measuring range -70~+10dBm/-50~+26dBm

Universal interface design, adapt to SC, ST, FC interface
Optional lithium battery, USB charging, easy to use
Equipped with LED lights, it is more convenient to check 
the line in the dark

Product parameter

9

KPM-11M Optical Power Meter User Manual

5

LED flashlight

Flashlight switch: Short press the "     " 
button to turn on the flashlight, which 
is convenient for use in a dark environment 
and realize the lighting function; short press 
the "    " button to turn off the flashlight.

Key  

 Function

REF/dB

Increased by 0.1dB

λ

Reduced by 0.1dB

save

Calibration function description

6

Press REF/dB first, and then press the +REF/dB keys simultaneously 
to enter the calibration mode. The λ key is to adjust the value down, a
nd the REF/dB key is to adjust the value up. Press the power button to 

save the value and exit the calibration procedure.

Wavelength (nm) 

800~1700nm

Power measurement 

range (dBm) 

-70~+10dBm / -50~+26dBm

Interface 

2.5mm universal connector

Power supply 

Rechargeable lithium battery 

1000mAh/7 AAA1.5V battery *2

Resolution (dB) 

0.01

Working temperature 

-10~+60(℃)

Storage temperature 

-25~+70(℃)

Volume/weight

Probe type

Charging interface

127x36.5x28mm /61g

InGaAs

USB charging (only charging models)

Working time 

20 hours with battery

Charge for 60 hours

This product uses a 650nm semiconductor laser as a light-emit-
ting device and is driven by a constant current source to emit a 
stable red light; it enters a single-mode or multi-mode fiber after 
being connected to an optical fiber interface to realize the 
function of fiber fault detection. It is an optical fiber engineering 
construction and optical fiber network. An indispensable tool for 
maintenance, optical device production and research.

Tips

11

Operating environment altitude: 

Area altitude below 2000m 

Please read all instructions and warnings before 

using this product. Irregular use will cause 

damage to the product or personal safety.

Use environment

1) Do not store this product in high temperature, strong light 

and strong magnetic fields, and do not place it in other harsh 

environments such as fire sources.

2)Improper use of the product may easily cause the product 

damage or may endanger personal and property safety.

3) If consumers violate the product manual and improperly 

use it, the personal and property damage caused by it will 

bearby yourselve, our company will not bear any legal 

responsibility.

4) Non-professionals are strictly prohibited from 

disassembling this product.
5) Avoid using electrical appliances or loads that exceed the 

output current of this product (the circuit will be protected 

and there will be no output).
6) Avoid strong physical effects, including knocking, throwing, 

trampling, squeezing, etc. 

Packing carton, optical power meter , 

certificate of conformity, instruction manual.

Standard configuration

Contact us:

KOMSHINE TECHNOLOGIES LIMITED
Tel : 

+86 25 66047688

Email : [email protected]

Add: 2F Bldg. D Qinheng Tech. Pk. Nanjing,

JS, 210001, China.

Website :www.KomShine.com

Reviews: