JP/LK:
Lock control jumper, to select the lock type(see 5.2.1 , 5.2.2).
•
Main Connect Port:
To connect the bus line and the electronic locks.
•
BUS: Connect to the bus line, no polarity.
•
PL: External lock power input, connect to the power positive(power +).
•
S+: Lock power(+) output.
•
S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
3.Specifications
•
Power Supply :
DC 24V;
•
Lock Power supply:
12Vdc, 300mA(Internal Power);
•
Power Consumtion: Standby 33mA; Working status 110mA;
•
Camera:
Color ARS; 500 TV Lines;
•
Unlocking time: 1~30s(Default 1s);
•
Working temperature:
-15ºC ~ 55ºC;
•
Dimension:
145(H)×90(W)×23(D)mm(Without rainy cover).
4.Mounting
4.1 Mounting Without Rainy Cover
The host kit is
installed on the wall.
Connect the cable correctly.
1
2
5
4
3
6
Placing name label.
The surface shell kits are
installed on the host kit.
Use the screw to fix the host.