TROUBLESHOOTING
WEAM012101
187
3.7.6 OTHER TROUBLES
(•) Always contact your Komatsu Distributor when you have to carry out this operation.
•
In case of anomalies or problems that are not listed here below, contact your Komatsu Distributor, who will pro-
vide for the necessary repairs.
3.7.6.1 ELECTRICAL SYSTEM
TROUBLE
CAUSE
SOLUTION
Lights do not work satisfactorily even
with engine running at high speed.
(•) Faulty cables
(•) Faulty fan belt tension.
(•) Blown fuse
(•) Check and repair any loose termi-
nals and connections.
• Adjust fan belt tension.
For details, see “EVERY 500
HOURS OF OPERATION”
• Change.
Lights come on intermittently with en-
gine running.
Battery charge warning light does not
go out even with engine running.
• Faulty alternator.
• Faulty cables.
(•) Change.
(•) Check and repair.
Alternator emits abnormal noise.
• Faulty alternator.
(•) Change.
Starter does not turn with ignition
switch in position ON.
• Faulty cables.
• Battery charge insufficient.
• Faulty fuse.
• Battery main switch turned to OFF.
(•) Check and repair.
• Charge battery.
• Change.
• Turn the switch to ON.
Starter pinion engages and disengag-
es repeatedly.
• Battery charge insufficient.
• Charge battery.
Starter makes engine run slowly.
• Battery charge insufficient.
• Faulty starter.
• Charge battery.
(•) Change.
Starter disengages before engine
start.
• Faulty cables.
• Battery charge insufficient.
(•) Check and repair.
• Charge battery.
Preheating warning light does not
come on.
• Faulty cables.
• Faulty bulb.
(•) Check and repair.
(•) Change.
Engine oil pressure warning light does
not come on when engine stops (igni-
tion key in position ON).
• Faulty bulb.
• Faulty oil pressure switch.
(•) Change.
(•) Change.
Summary of Contents for PC18MR-3
Page 2: ......
Page 16: ...14 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 24: ...22 PAGE INTENTIONALLY LEFT BLANK...
Page 25: ...SAFETY AND ACCIDENT PREVENTION 23...
Page 78: ...76 PAGE INTENTIONALLY LEFT BLANK...
Page 79: ...THE MACHINE AND ITS OPERATIONS 77...
Page 192: ...190 PAGE INTENTIONALLY LEFT BLANK...
Page 193: ...MAINTENANCE 191...
Page 255: ...TECHNICAL SPECIFICATIONS 253...
Page 263: ...AUTHORISED OPTIONAL EQUIPMENT 261...
Page 282: ...280 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 283: ......
Page 284: ...2010 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2010...