Page
15
Issue date
:
Controlled document
:
Revision:
WA900-3EO
SERVICE INTERVALS
MAINTENANCE SCHEDULE
Air conditioning
IMPORTANT
The air conditioning system must be run for a minimum of
five minutes each week regardless of the season to
lubricate the system and prevent damage to the seals.
Ensure a qualified technician is employed for any
repairs required.
To ensure dependable efficient operation, all air conditioning units
require a certain amount of Preventative Maintenance to be carried
out at regular intervals between services.
These regular inspections will ensure that the unit is always
operating at peak efficiency and will provide early warning of
potential problems, which if left unattended, may incur costly
machine down-time.
It is strongly recommended that an annual service programme be
implemented. This full unit service should be carried out once a
year, generally just prior to the beginning of the warmer season.
This service should only be carried out by a qualified refrigeration
mechanic and should involve a full function test of the complete
system, as well as checking of component settings.
The following tables show are our suggested maintenance schedule
for all units .
DAILY INSPECTION
Component / System
Inspection Required
Return air filters
Check for cleanliness and deterioration.
Refrigeration hoses.
Check for damage or deterioration.
Fresh air filtration.
Check pre-cleaner for damage or deterioration.
MONTHLY INSPECTION
Component / System
Inspection Required
Condenser coil.
Check for cleanliness.
Evaporator coil.
Check for cleanliness.
Condenser fan motors.
Clean motors with dry compressed air.