CENTRAL HEATING BOILER 

TEMPERATURE 

DIGITAL DRIVER 

„TIGRA”

 

MANUAL

SUPPORT SERVICES: PHONE NUMBER - 0 796 793 796

Summary of Contents for TIGRA

Page 1: ...Street 11A Phone number 62 594 33 04 62 594 32 96 www kom ster pl e mail biuro kom ster pl SERVICE Phone number 0 796 793 796 CENTRAL HEATING BOILER TEMPERATURE DIGITAL DRIVER TIGRA MANUAL SUPPORT SERVICES PHONE NUMBER 0 796 793 796 ...

Page 2: ...emperature higher than 90 C 17 9 2 Water temperature in the range of 80 90 C 18 9 3 Screw feeder s pipe overheating alarm 18 9 4 Temperature drop alarm 19 9 5 Anti frost alarm 19 9 6 Thermal alarm hardware protection 19 10 Temperature sensor failure alarms 20 C H sensor failure breakdown of Tfeed Tflo Th w Tcir 11 Modes D N ECO ROOM NORM CAL 24 12 Circulation pumps handling 24 12 1 Central heating...

Page 3: ...ote control panels identical to the main panel mounted next to the boiler You can ask for the opportunity to buy additional control panels under the telephone number 62 594 33 04 0 796 793 796 or e mail biuro kom ster pl The manufacturer provides additional options such as connection of WiFi module GSM and TV to the driver In this case the connector on rear wall of the housing is used The connecto...

Page 4: ... 5 A Floor pump 0 8A Cir Pump 0 8A Circulation pump Anti Stop 1 min every 7 days Auto pump start anti frost Less than 5 C External breakdown thermostat start feeder and fan lock More than 85 C Software security enable More than 90 C Number of time zones 24 for each day Possibility to connect remote controls YES max 4 panels H W pump handling YES Circulation pump handling YES Floor pump handling YE...

Page 5: ...nnectors SOCKETS PLUG IN THE DRIVER Connection on the side of plugs attached to the driver 1 Connect the green yellow wire GROUND to the central pin PE in the plug 2 Connect brown and blue wire N and L 230V to the pins according to marks in the picture L brown PHASE N blue ZERO NEUTRAL 3 Check whether the connections are correct Principle of wire connection on the circulation pumps 1 Take off the ...

Page 6: ... respectively 0 1 2 3 This number is displayed when turning on the driver by the network button on the splash screen It is also visible on the tally of every panel 0 panel is the basic main panel screwed to the main housing of the driver or directly connected to the housing when the main panel is mounted on the boiler and upper housing for example behind the container or on rear side wall of the b...

Page 7: ...es power supply red and blue wire and data transmission black and white wire Description of the panel socket and connection schematic are placed in every panel on rear wall of the housing and in the manual Description of driver s socket connectors can be found below There is a possibility to power the panel from independent power supply 12V connected to the wall socket 230V near the device and con...

Page 8: ...he picture as INFO i INFO black and white wires In order to supply the panel directly from the driver you can use two additional pins outer in the panel and two upper in the connector of the driver red and blue wires Panel can be also powered directly from an independent power supply 12V If the panel has an independent supply you can use only a 2 wire cable transmitting data INFO and INFO No suppl...

Page 9: ...10 C C H pump start temperature 35 Off 25 70 C H W temperature Off Details in the further part of the manual C Time of supplying 15 Off 1 205 S Feed period 90 1 150 S Feed count 2 Off 1 20 Blow time 10 Off 5 59 S Blow break 10 1 99 Min Blower level 50 10 100 Rotations in the running state 50 10 100 Driver switch off temperature 30 25 35 C 8 ...

Page 10: ...imal blower level 55 20 70 No fuel recovery time 90 Off 90 Min Time to stop the pump 3 1 250 Min H W container priority NO YES NO Feeder alarm temp 70 Off 35 90 C Clearence time 5 1 30 min Circulation pump stop temperature OFF OFF 70 C FLOOR temperature OFF OFF 50 C Language POLIS H POLISH CZECH ENGLISH Fire setting time 2 hours 1 7 Hour Extinction time 2 hours 1 7 Hour 9 ...

Page 11: ...1p m 6a m by a value set in the menu Night Correction ECO The driver automatically decreases temperature independently from the time of day by a value set in the menu Economic Correction CAL Work according to the calendar The driver in this mode implements the program set by its user You can set the temperature correction and enabling disabling of the individual pumps depending on the hour Calenda...

Page 12: ...parameter of function down 3 In the manual operation mode when the fan is enabled this button is used to decrease its rotations ENTER this button is used to accept switch to edition mode of the function you want to change accept entered changes saving This button causes switching to OFF mode when the boiler is enabled Fan and feeder are disabled independently from the temperature Circulation pumps...

Page 13: ...to enable disable the fuel feeder Explanations of the use of buttons for changing the calendar functions and changing the time are described in the further part of the manual para 6 6 1 DIODES INDICATING THE OPERATION OF EXTERNAL DEVICES FEEDER FAN CENTRAL HEATING PUMP H W PUMP UNDERFLOOR HEATING PUMP CIRCULATION PUMP Additionally the panel is equipped with Is a diode indicating temperature set on...

Page 14: ...operating modes in para 11 In the OFF mode you can make any changes in menu because the driver is in standby fan and fuel feeder are not active The device can be switched to BURNING UP operating mode using the button inscription BURNING UP will be then displayed Pressing again this button will cause a return to the standby mode OFF 7 2 Changing the function parameters in the driver menu Any functi...

Page 15: ...hould find the screen MANUALOPERATION Using this button you can accept and turn on the manual operation The screen will change its color to green It indicates that the manual operation function is enabled From that moment you can enable disable the following receivers fan button fuel feeder button central heating circulation pump button Using this button you can enable the feeder to supply the fue...

Page 16: ...on of the device Not following the manufacturer s suggestions and burning in lower temperatures may cause the central heating boiler warranty expire Automatic fire setting is indicated by BURNING UP message on the main display When the boiler reaches the set temperature inscription RUNNING appears During automatic burning up you should properly choose the parameters FEED TIME FEED PERIOD and BLOWE...

Page 17: ...l will not be supplied When temperature drops below the set minus the value of histeresis the drives switches to the REGULATION operating mode A dose of fuel is automatically supplied and blower starts In the REGULATION mode it is enabled with a frequency set by using the function FEED TIME and FEED PERIOD Fan works all the time increasing the heat to achieve the set temperature again The drive wi...

Page 18: ...s 9 1 Water temperature higher than 90 C A very important alarm informing about dangerously high water temperature in the boiler that leads to boiling the fluid in the central heating installation The alarm is enabled at more than 90 C The driver display color changes to RED Red diode ALARM lights up and enables the sound alarm During the alarm temperature more than 90 C the feeder and fan are swi...

Page 19: ...in a special bushing intended for this purpose controls the temperature of the screw in the pipe up to speed When somehow the heat goes back towards the container warming the screw to a dangerously high temperature factory setting 70 C possibility of change the driver enables the alarm The display starts blinking red The sound alarm is activated For safety the driver enables the feeder for a speci...

Page 20: ...can define the time after which the driver is to indicate such a drop It can be any value depending on the user needs Set the parameter of function NO FUEL RECOVERY TIME to OFF when you do not want the driver to inform you about the temperature drop 9 5 ANTI FROST ALARM The driver automatically enables circulation pumps during temperature drop below 5 C in order to mix water in the installation an...

Page 21: ...ditional independent thermostat protects installation when the central heating boiler main sensor fails 10 TEMPERATURE SENSOR FAILURE ALARMS Every sensor of the driver TIGRA examines up to speed the temperature in the place where it was connected Lack of measure temperature indicates its damage In the case of damage of the boiler main sensor it is necessary to change it to a new one It is not poss...

Page 22: ...iler until the sensor is exchanged into a new one INSCRIPTION ON THE DISPLAY C H SENSOR FAILURE MUST REPAIR This inscription and accompanying sound signal lit alarm diode indicate damage of the central heating boiler main sensor Digit 000 appears on the red display instead of temperature readings It is not possible to keep using the driver without a new sensor Please contact the service 0 796 793 ...

Page 23: ...ot work the driver will not indicate broken sensor error To buy a new sensor contact the service 0 796 793 796 Tcir BREAKDOWN This inscription on the display and accompanying sound alarm lit alarm diode indicate broken circulation pump sensor When the sensor is broken you can delete the alarm and continue to use the possibility to enable the pump in emergency mode Just set the maximal possible val...

Page 24: ...ically deleted No measurement will indicate the pump work regardless of the measurement of the broken sensor and thus work without interruption Heating the water container will be possible until the sensor is exchanged work in emergency mode max 7 days The second way to delete the alarm is set the value of function H W TEMPERATURE to OFF The pump will not work the driver will not indicate the brok...

Page 25: ...ected proportionatelytothe value of settemperature decrease ROOM Work with the room thermostat When the set temperature in a room is reached the driver switches to forced running and cyclically enables disables the central heating pump Principle of cooperation with the thermostat and selection of the appropriate model was described in thefurther part of themanual In the ECO mode H Wandcirculation ...

Page 26: ... it is switched off while reaching the set temperature in the room When temperature in a room is reached a cyclic operating mode of the pump starts The driver switches the pump on for 30 seconds and the pump down time is as much as you set using the function TIME TO STOP CENTRAL HEATING PUMP service setting 12 2 DOMESTIC HOT WATER PUMP Set to OFF by default Diode indicating its work To start the H...

Page 27: ...ser more important than water temperature in the boiler 12 3 DOMESTIC HOT WATER PRIORITY When we use H W priority the central heating pump is switched off while heating the H W container You should set the function H W PRIORITY to the value YES on Factory setting is NO off Due to the active priority you can set temperature in the container to a higher value than water temperature in the boiler Max...

Page 28: ...ill drop to boiler set temperature 12 4 UNDERFLOOR HEATING PUMP Diode indicating its work Factory setting OFF Water set temperature in the underfloor heating system is set using the function FLOOR TEMPERATURE service setting no more than the C H temperature set and no more if the boiler set temperature is higher than 50 C than 50 C safety issues Temperature in the floor system is considered reache...

Page 29: ...h as 70 degrees or mounting the sensor on the boiler and not in an independent measure place you can set the continuous circulation pump mode as in the drivers without additional sensor that enable disable the circulation pump using ONLY water temperature in the central heating boiler as a base to implement on off cycles of the circulation pump 1 Circulation pump stop temperature can be set using ...

Page 30: ...iver clock is reset Reset of the current time and day of week is required When the driver is on the driver clock reset will not be possible SETTING THE CURRENT WEEKDAYAND HOUR To set the current time find the function SET TIME in the menu Confirm the change using the button Inscription SET HOUR will be displayed Again confirm by pressing the button The display color will change to green Time editi...

Page 31: ... precise but complex and time consuming program procedure of the calendar a very simple time zone the so called DAY NIGHT was introduced This time zone ensures decreasing the night temperature in constant hours 11p m 6a m by clicking one button Using the advanced calendar and simple DAY NIGHTtime zone is described below 14 1 DAY NIGHT MODE Day night mode displayed as D N mode is a simple time zone...

Page 32: ...ur you can also activate or deactivate the circulation pumps HDW underfloor heating and circulation pumps by setting them so that at a certain time one of the pumps switches off or on and work depending on temperature settings The driver uses calendar mode and implement program set by the user when the driver works in CAL mode Find the function CALENDAR in the menu When you want to edit the calend...

Page 33: ...e switch off of a certain pump 0 at a certain time or switch on 1 so that it works according to the temperature settings as in the normal mode 1 in the menu is the pump work while 0 is switching off the pump at a certain hour In this way you can program each day in a week and every hour Everything you set at eg 3p m will be implemented until 4p m If you want the temperature drop by the correction ...

Page 34: ... sensor This sensor examines temperature of the pipe in which the fuel is supplied by the screw Alarm program is implemented on the basis of temperature measurement In the case of exceeding the set temperature in the function FEEDER OVERTEMPER ALARM fuel is cleared clearence time is set in the function CLEARENCE TIME It is to push out the heat from the feeder pipe The sensor should be mounted dire...

Page 35: ... water oil etc while assembly and operation pay special attention that the sensor wires can not contact the hot elements of the installation Alarms concerning broken sensors are described in para 10 in this manual Any moment of the driver operation you can preview the current temperature of every sensor One of the menu screens allows the possibility to preview temperature in the following order fr...

Page 36: ...the pause between the next doses of fuel set by the function FEED TIME Feed count function active in RUNNING state It is a value that means how many blows have to pass until the feeder switches on in order to supply the fuel Feed count is obtained in RUNNING state Depending on the count set to eg 2 the feeder will start every second blow and supply the fuel accordingly to the value of BLOW TIME If...

Page 37: ...de green display will result in displaying NO By changing it to YES and confirming the change you can restore factory settings SERVICE MODE for advanced users Minimal temperature Minimal temperature that can be set on the driver Maximal temperature Maximal temperature that can be set on the driver Histeresis Boiler histeresis temperature It is the value by which the temperature is to drop below th...

Page 38: ... in ROOM mode during contacts short circuit reaching the room temperature The parameter set to eg 4 means that the pump will switch off after 4 min and after that time it switches on for 30 s the value of 30 s is a constant value it is always the time of pump start Setting the parameter of TIME TO STOP THE PUMP you set the break in the pump operation After that break the pump will switch on for 30...

Page 39: ...s basis the boiler temperature is controlled and the central heating circulation pump is switched on and off The room driver after connecting receives a higher priority The room thermostat can be connected via a 2 wire cable Common room thermostats using the normally open normally closed bistable relay From the driver TIGRA you should use cinch plug using which you can connect cables connecting wi...

Page 40: ...less than 40 C the driver does not switch off the blow and does not stop the feeder cycle The fan and feeder work until the moment of reaching the boiler temperature of 40 C Above this temperature the driver switches to the running state and normally implements the cycle of blows as in the RUNNING state If the room temperature will be greater than the set on thermostat TIGRA will keep on the boile...

Page 41: ...power plug from the wall socket 3 During setting fire or surges unplug the driver from the wall socket 4 During the confusion or problems with the installation of the controller please contact the appropriate person Telephone number is shown on the cover page of this manual 5 The driver assembly should be done by a qualified person Improper installation especially the connection of external device...