4.5
Disassembling
Observe the sequence below, if a servo amplifier has to be disassembled (e.g. for replacement).
1. Electrical disconnection
Switch off the main switch of the switchgear cabinet and the fuses that supply the
system.
Wait at least eight minutes after disconnecting the servo amplifier from the main
supply power before touching potentially live sections of the equipment (e.g.
contacts) or undoing any connections. To be sure, measure the voltage in the DC
Bus link and wait until it has fallen below 40V.
Remove the connectors. Disconnect the earth (ground) connection at last.
2. Check temperature
During operation the heat sink of the servo amplifier may reach temperatures
above 80°C (176°F). Before touching the device, check the temperature and wait
until it has cooled down below 40°C (104°F).
3. Disassembling
Remove the fan housing and disassemble the servo amplifier (reverse of the procedure described
in chapter "Mechanical installation).
4.6
Repair
Repair of the servo amplifier must be done by the manufacturer. Opening the devices means loss of
the guarantee. Use the telefax form on page 116 for repair request. You'll receive the current dis-
patch information.
Disassemble the equipment as described in chapter 4.5 and send it in the original packaging to the
address given in the dispatch information.
4.7
Disposal
In accordance to the WEEE-2002/96/EC-Guidelines we take old devices and accessories back for
professional disposal. Transport costs are the responsibility of the sender. Use the telefax form on
page 116 for disposal request. You'll receive the current dispatch information.
Disassemble the equipment as described in chapter 4.5 and send it in the original packaging to the
address given in the dispatch information.
16
SERVOSTAR
®
640/670 Instructions Manual
Handling
12/2010
Kollmorgen