2.1.5
Connection diagram
Layout of the sercos
®
bus system in ring topology, with optical fibre cables (schematic
with S700).
2.1.6
Modifying the station address
The amplifier address can be set to a value between 0 and 63. With address 0, the
amplifier is assigned only as a repeater in the sercos
®
ring.
There are various ways to set the station address:
Setup software
The sercos
®
address can be modified in the setup software. For additional information,
please refer to the online help in the Setup Software.
Alternatively, enter the command
ADDR #
in the “Terminal” screen, where # is the new
address of the amplifier. An amplifier SAVE and COLDSTART is required for the new
address to take affect.
Keys on the front of the servo amplifier
The sercos
®
address can also be modified using the keys on the front of the servo
amplifier. (For additional information, please refer to the instructions manuals).