Kollmorgen AKI-CDT-MOD-04T Installation Manual Download Page 10

Graphic Operator Terminal / 

TECHNICAL SPECIFICATIONS

 

 

3 TECHNICAL 

SPECIFICATIONS 

This chapter provides the technical specifications for the graphic operator terminal. 

3.1   Technical Data 

The following table provides the electrical and mechanical specifications for the graphic operator 
terminal. 

Parameters 

AKI-CDT-MOD-04T 

Front panel 

155.8 x 119 x 6 mm (W x H x D) 

Mounting depth 

57 mm (157 mm including clearance) 

Front panel seal 

IP 66 

Rear panel seal 

IP 20 

Touch screen 
material 

Touch screen: Polyester on glass, 1 million finger touch 
operations. Overlay: Autotex F157/F207 *. 

Reverse side material  Powder-coated aluminum 

Weight 

0.6 kg 

Serial port  
RS422 / RS485 

25-pin D-sub contact, chassis-mounted female with 
standard locking screws 4-40 UNC. 

Serial port RS232C 

9-pin D-sub contact, male with standard locking screws 4-
40 UNC. 

Ethernet 

Shielded RJ 45 

USB 

Host type A (USB 1.1), max output current 500 mA 

Real time clock 

±20 PPM + error because of ambient temperature and 
supply voltage.  
 
Total maximum error: 1 min/month at 25 °C 

Temperature coefficient: -0.034 ± 0.006 ppm/°C

2

 

Real time clock 
battery 

CR2450 (UL and cUL: Sanyo or Panasonic) Minimum 
lifetime: 3 years 

Power consumption 
at rated voltage 

Normal: 0.15 A  
Maximum: 0.35 A 

Display 

TFT-LCD. 320 x 240 pixels, 64K colors. LED backlight 
lifetime at the ambient temperature of +25 °C: >10,000 h. 

Active area of display 

70.1 x 52.6 mm 

Fuse 

Internal DC fuse, 2.0 AT, 5 x 20 mm 

 

10

Summary of Contents for AKI-CDT-MOD-04T

Page 1: ...rminal Installation Manual Revision 1 1 August 2011 AKI CDT MOD 04T 3 5 Touchscreen HMI Keep all manuals as a product component during the life span of the product Pass all manuals to future users own...

Page 2: ...may not be disclosed to third parties translated copied or duplicated in any form in whole or in part without the express written permission of Kollmorgen Registered Trademarks Kollmorgen is a regist...

Page 3: ...Chemical Resistance 4 1 Metal Casing 12 4 2 Touch Screen and Overlay 13 4 3 Autotex F157 F207 13 4 4 Touch Screen Surface 14 4 5 Touch Screen Protector 14 5 Operator Terminal Diagrams 5 1 Communicati...

Page 4: ...arefully Check the delivery for transportation damage If damage is found notify the supplier as soon as possible Do not use the graphic operator terminal in an environment with high explosive hazards...

Page 5: ...correct before connecting the product to the power outlet Peripheral equipment must be appropriate for the application and location 1 2 2 During Use Keep the graphic operator terminal clean Emergency...

Page 6: ...0 35 inch Space requirements when installing the graphic operator terminal CAUTION The openings on the enclosure are for air convection Do not cover these openings 2 2 Installation Process 1 Unpack an...

Page 7: ...e controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur B Use an M5 screw and a grounding conductor as short as possible with a cross...

Page 8: ...ode switches DIP switches located on the rear side of the operator terminal All mode switches must be in OFF position during graphic operator terminal use The mode switches should not be touched unles...

Page 9: ...ing the file system in the operator panel are deleted when upgrading with Image Loader 1000 Service Menu mode the service menu for the system program is shown Allows the user to set IP configuration e...

Page 10: ...coated aluminum Weight 0 6 kg Serial port RS422 RS485 25 pin D sub contact chassis mounted female with standard locking screws 4 40 UNC Serial port RS232C 9 pin D sub contact male with standard lockin...

Page 11: ...the requirements for class II power supplies Ambient temperature Vertical installation 0 to 50 C Horizontal installation 0 to 40 C Storage temperature 20 to 70 C Relative humidity 5 85 non condensed...

Page 12: ...3 Tap water The powder paint shows limited resistance to the following chemicals at room temperature Chemicals Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric ac...

Page 13: ...Gumption1 SBP 60 951 Ariel powder in solution1 Hydrochloric acid 36 Sulfuric acid 10 Bleach1 Linseed oil Tomato ketchup Castor oil Methanol Tricjloroacetic acid 50 Caustic soda 40 1 Nitric acid 10 Whi...

Page 14: ...e 5 hours 4 5 Touch Screen Protector It is recommended to use the Touch Screen Protector film that can be ordered from Kollmorgen Solvent Resistance The Touch Screen Protector film withstands exposure...

Page 15: ...Graphic Operator Terminal OPERATOR TERMINAL DIAGRAMS 5 OPERATOR TERMINAL DIAGRAMS This chapter provides the operator terminal diagrams 5 1 Communication Port Diagrams 15...

Page 16: ...Graphic Operator Terminal OPERATOR TERMINAL DIAGRAMS 16 5 2 Outline Diagrams...

Page 17: ...inet Connect a 2 5 mm2 wire between the graphic operator terminal s quick connect plinth and the terminal chassis Connect a 6 or 4 mm2 wire or grounding braid between the terminal s chassis and the cl...

Page 18: ...assis via a capacitor The graphic operator terminal s Ethernet shield is directly connected to the chassis Check whether the other Ethernet unit has its shield directly grounded or grounded via a capa...

Page 19: ...ations for the relevant bus standard Use shielded cabling for Ethernet preferably with foil braided shield D sub covers should be shielded and the shield should be connected to the cover 360 where the...

Page 20: ...vided in the specifications The ambient temperature refers to the temperature in the device cabinet which cools the terminal s electronics In most cases the ambient temperature for the graphic operato...

Page 21: ...nuous use If a thermostat is installed the fan only needs to come on when needed Large graphic terminals draw only one fifth of the current when the background lighting is off The loss effect drops fr...

Page 22: ...ds Connect 0 V on the 24 V feed to the ground This offers three advantages Safety is increased The 24 V feed will not be live in the event of a faulty connection or short circuit between 0 V 24 V and...

Page 23: ...The pair capacitance may not exceed 52 5 pF m and area at least 0 25 mm2 AWG 24 if you want to use the maximum transfer distance and maximum transfer speed 0 V the reference voltage for communication...

Page 24: ...AKI CDT MOD 04T 3 5 Touch screen HMI A 1 AKI CDT MOD 04T 3 5 Front View 1 155 8mm 119 mm A 2 AKI CDT MOD 04T 3 5 Front View 2 24 Cut out Terminal outline Panel cut out for 3 5 mm display Front View S...

Page 25: ...erator Terminal APPENDIX A A 3 AKI CDT MOD 04T 3 5 Bottom View COM2 RS232 COM1 RS422 485 24VDC A 4 AKI CDT MOD 04T 3 5 Side View max 7 5 mm material thickness 57 mm Battery DIP switch USB host Etherne...

Page 26: ...Graphic Operator Terminal APPENDIX A A 5 AKI CDT MOD 04T 3 5 Back View 137 4mm 102 7 mm 9 7 mm 9 mm 8 mm 9 7 mm 26...

Page 27: ...ugh solutions that are unmatched in performance reliability and ease of use giving machine builders an irrefutable marketplace advantage For assistance with your application needs contact us at 540 63...

Reviews: