AKD2G-S Installation, Safety 1 | 8 Electrical Installation
8.6 Power and Logic Voltage Supply (X3/X10)
8.6.1 Mains power supply (X3)
Drives in the AKD2G series can be supplied as follows:
AKD2G-Sxx-6V
1, 2 or 3 phase industrial AC supply networks: 120 V or 240 V.
DC supply networks: on request.
AKD2G-Sxx-7V
3 phase industrial AC supply networks: 240 V, 400 V or 480 V.
DC supply networks: on request.
Connection to other voltage types of AC supply networks is possible with an additional isol-
ating transformer.
Periodic overvoltages between phases (L1, L2, L3) and the housing of the drive must not
exceed 1000 V peak.
In accordance with IEC 61800, voltage spikes (< 50 µs) between phases must not exceed
1000 V. Voltage spikes (< 50 µs) between a phase and the housing must not exceed 2000 V.
8 pin, pitch 7.62 mm
optional T version
Wiring example:
1 phase AC supply (
2 phase AC supply (
3 phase AC supply (
DC supply (
AKD2G-Sxx-6V requires external EMC filter for use in
industrial environment, product category C.
Mating connector data see (
Pin Signal
Description
1
PE
Protective earth
2
L1
3~ mains supply L1, 1~ supply L, DC
3
L2
3~ mains supply L2
4
L3
3~ mains supply L3, 1~ supply N, DC supply -