AKD PDMM User Guide | 44.1 SM.I1
44.1 SM.I1
General Information
Type
NV Parameter
Description Sets service motion current 1; active in opmode 0 (torque) only.
Units
A
Range
–Drive peak current to +Drive peak current
Default
Value
0.025 ∙ Drive peak current
Data Type
Float
See Also
SM.ACCTYPE, SM.I2, SM.MODE, SM.MOVE, SM.T1, SM.T2, SM.V1,
SM.V2, SM.VPM1, SM.VPM2
Start Ver-
sion
M_01-00-00-000
Description
SM.I1 defines the current that is used in service motion modes 0 and 1 (see SM.MODE (pg
431)).
Related Topics
44.2 SM.I2
General Information
Type
NV Parameter
Description Sets service motion current 2; active in opmode 0 (torque) only.
Units
A
Range
–Drive peak current to +Drive peak current
Default
Value
0.025 ∙ Drive peak current
Data Type
Float
See Also
SM.ACCTYPE, SM.I1, SM.MODE, SM.MOVE, SM.T1, SM.T2, SM.V1,
SM.V2, SM.VPM1, SM.VPM2
Start Ver-
sion
M_01-00-00-000
Description
SM.I2 defines the current that is used in service motion mode 1 (see SM.MODE (pg 431)).
Related Topics
44.3 SM.MODE
General Information
Type
NV Parameter
Description Sets the service motion mode.
Units
N/A
431
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...