AKD PDMM User Guide | 22.1 AOUT.CUTOFF
22.1 AOUT.CUTOFF
General Information
Type
NV Parameter
Description
Sets the analog output low-pass filter cutoff
frequency.
Units
Hz
Range
0 to 10,000 Hz
Default
Value
0 Hz
Data Type
Float
See Also
Start Version M_01-04-01
Fieldbus Information
Description
AOUT.CUTOFF sets the cutoff frequency in Hz for a single-pole low-pass
filter on the Analog Output.
A value of 0 Hz will turn off the filter and will allow all frequencies to pass through.
The filter can be used with all modes of Analog Output.
Related Topics
22.2 AOUT.ISCALE
General Information
Type
NV Parameter
Description
Sets the analog current scale fac-
tor.
Units
A/V
Range
0.001 to 22.4 A/V
Default
Value
0.001 to 22.4 A/V
Data Type
Float
See Also
Start Version M_01-01-01-000
Fieldbus Information
Description
AOUT.ISCALE sets the analog current scale factor that scales the analog output
(AOUT.VALUE) for AOUT.MODE = 4 or 5. The value entered is the motor current per 10 V of
analog input or output. This value may be either higher or lower than 100%, but the actual
analog I/O will be limited by the application current limit (IL.LIMITN (pg 360) and IL.LIMITP (pg
361)).
Related Topics
212
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...