3.4.5 Uninstalling
If a drive must be uninstalled (such as for replacement), remove the drive as follows:
1. Switch off the main switch of the switchgear cabinet and the fuses that supply the sys-
tem.
WARNING
Contacts can still have dangerous voltage present up to seven minutes
after switching off mains voltage. Risk of electrical shock! Wait at least
seven minutes after disconnecting the drive from the main supply power
before touching potentially live sections of the equipment (e.g. contacts)
or undoing any connections. Always measure the voltage in the DC bus
link at connector X14 at AKD-C and wait until the voltage is below 60 V
before handling components.
2. Remove the connectors. Disconnect the potential earth connection last.
3. Check temperature.
CAUTION
During operation, the heat sink of the drive may reach temperatures
above 80 °C (176 °F). Risk of minor burns. Before touching the device,
check the temperature and wait until it has cooled below 40 °C (104 °F).
4. Uninstall. Remove the AKD-N.
3.4.6 Repair and disposal
Only the manufacturer can repair the drive. Opening the device voids the warranty. Uninstall
the drive as described in "Uninstalling" (
p. 15), then send the drive in the original pack-
aging to the manufacturer (see table below). Transport costs are the responsibility of the
senders.
In accordance with the WEEE-2002/96/EC-Guidelines and similar, the manufacturer
accepts returns of old devices and accessories for professional disposal. Transport costs
are the responsibility of the sender. Send the devices to the manufacturer addresses shown
in the table below.
USA
Europe
Kollmorgen
201 West Rock Road
Radford, VA 24141
KOLLMORGEN Europe GmbH
Pempelfurtstr. 1
D-40880 Ratingen
AKD-N Installation | 3 Safety
Kollmorgen | December 2014
15