9.13 Push-button (B1)
The push-button can be used to start predefined functions.
Press short to display the IP address in the LED display
9.14 Rotary Switches (S1), Setting IP address
The configured IP address will be displayed on the 7 segment
at Ethernet cable connection time and at power-on, if an Eth-
ernet cable is connected. If no Ethernet cable is connected,
no IP address will be indicated in the display.
More information is available in the AKD-C User Guide or in
the Settings Screen-> Fieldbus-> TCP/IP screen in
WorkBench.
Set S1 to 0 (zero) for DHCP/AutoIP address.
S1 Setting AKD-C IP Address
0
DHCP/AutoIP address. The IP address of the AKD-C is obtained from the
DHCP server on your network. If no DHCP server is found the IP addresses
is an AutoIP address (it is internally generated following the AutoIP protocol
and will be of the form 169.254.x.x).
1 to 9
Prepared for Static IP Address. Currently out of function.
The PC subnet mask must be set to 255.255.255.0 or 255.255.255.128
Dynamic IP addressing (DHCP and Auto-IP)
With S1 set to 0, the device is in DHCP mode. The AKD-C will acquire its IP address from
an external DHCP server if present in the network. If a DHCP server is not present, the
AKD-C will assume an Automatic Private IP Address of the form 169.254.x.x.
If your PC or PAC is directly connected to the AKD-C , and set to obtain an IP address auto-
matically in the TCP/IP settings, a connection will be established with both devices using
compatible automatic generated addresses. It can take up to 60 seconds for a PC to con-
figure an Automatic Private IP Address (169.254.x.x).
Changing the IP address
If the switch is altered while 24 V Logic power is supplied to the AKD-C , you must switch off
and then switch on again the 24 V supply voltage. This action will reset the address.
AKD-C Installation | 9 Electrical Installation
Kollmorgen | kdn.kollmorgen.com | February 2018
79