background image

2019 Kolibri USA

KB-062019

 Cleaning Procedure

 

KCD-1000

Dirty sensors can affect the KCD-1000 performance and cause genuine bills to be rejected. It is suggested that 

the user performs weekly maintenance on the unit to maintain top performance.

Items Needed

            - Soft microfiber cloth

            - Soft-bristled brush

            - Can of compressed air

            - Isopropyl alcohol

Steps

 

1. First, make sure the unit is turned off and unplugged

 

2. Perform the cleaning of each sensor, one step at a time (a to c), and check after each step if this 

                   resolves the issue. If it does not, proceed to the next cleaning step

 

 

a. Wipe away dust with a soft microfiber cloth or a soft-bristled brush

 

 

b. Clean the sensors using a can of compressed air

 

 

c. Clean the sensors with a cotton swab 

lightly

 moistened with isopropyl alcohol – gently wipe 

                                 

 

the sensors with the swab

Refer to the photos below showing the location of the KCD-1000 sensors. For each sensor, follow the steps as 

described above.

Sensors Locations

Overview:

 

1. UV Sensor

 

2. IR Sensors

 

3. Magnetic Sensors

 

4. Start Sensor

2

3

4

1

Reviews:

Related manuals for KCD-1000