Koldfront PACI12020CSV Owner'S Manual Download Page 22

 

17 

 

 

 

Cleaning and Maintenance 

 

 

Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s 
life. Be sure to always unplug the air conditioner from the power outlet before cleaning. 

Cleaning the Unit 

Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the 
unit. 
Use a soft bristle brush to clean between the vents.  
Carefully use a vacuum cleaner to clean the condenser coils 

 

Never use abrasive chemicals, volatile substances, gasoline, detergents, chemically treated cloths, or other 
cleaning solvents that may damage the cabinet exterior. 

 

Never spray water directly on the unit. 
 

Cleaning the Pre-Filter 

To clean the pre-filter, follow the steps below: 
1.

 

Power off the unit and remove the pre-filter.  

2.

 

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse thoroughly under 
lukewarm running water (below 104° F). You may use a mild soap and water solution if needed. Allow 
the pre-filter to air dry in a cool and shaded place. Dry the pre-filter thoroughly before reinstalling it.  

 

Clean the pre-filter periodically. If the unit is used in a dusty environment you may need to clean it on a 
weekly basis.  
 
 
 
 

Preparation for Storage 

If you are not going to be using the unit for an extended period of time, follow the instructions below before 
storing your unit: 
1.

 

Drain all the water from the unit’s reservoir. Operate the unit in fan mode for a few hours to thoroughly 
dry any moisture left on the coils inside the unit.  

2.

 

Power off the unit, and clean or change the filter. 

3.

 

Unplug and carefully wind the power cord. 

4.

 

Remove the exhaust hose and duct connectors and keep them in a safe place. 

 

 
 

 

Warning: Never operate the unit without the filter. 

Summary of Contents for PACI12020CSV

Page 1: ...ioner PACI12020CSV Owner s Manual For more information on other great Koldfront or EdgeStar products on the web go to http www edgestar com To use the self diagnostic tool go to https support edgestar...

Page 2: ...ppropriate amperage If the power cord is damaged it must be replaced by the manufacturer a service agent or qualified technician Do not remove any part of the casing unless you are instructed to do so...

Page 3: ...power cord to a grounded outlet 2 Press the TEST button on the LCDI plug This should trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the u...

Page 4: ...NECTORS TO THE EXHAUST HOSE 6 CONNECTING THE DUCT CONNECTOR TO THE UNIT 6 CONNECTING THE DUCT CONNECTOR TO THE GRATED ADAPTER 7 NOTES ABOUT THE EXHAUST HOSE 7 Draining the Unit 8 DRAINAGE OPTIONS 8 Op...

Page 5: ...d packaging materials in case you need to move or ship the appliance in the future Allow the unit to stand for at least 24 hours before you use it this allows the cooling components time to settle fro...

Page 6: ...label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service und...

Page 7: ...2 Parts Identification FRONT VIEW BACK VIEW Caution Make sure the drain plug is firmly installed before using the unit to prevent leaking...

Page 8: ...you begin make sure you have all the parts necessary for installation WINDOW KIT PARTS LIST PARTS FOR CONTINUOUS AND MISTING DRAINAGE Note There is one duct connector that includes an opening for the...

Page 9: ...conditioner Your window kit can be installed on a horizontal or vertical sliding window as shown in the following pictures INSTALLING THE GRATED ADAPTER 1 Insert the round grated adapters through the...

Page 10: ...INDOW PLATES 3 Open your window and place the window kit with grooved side facing outward on the window sill Then slide the window kit plate to fit the width of the window You can use screws to secure...

Page 11: ...ps 6 Roll the unit towards the window kit Leave a space that is at least 20 inches to the wall CONNECTING THE DUCT CONNECTOR TO THE UNIT 7 Align the slots on the duct connector to the tabs and snap th...

Page 12: ...ill be expelled out of the exhaust port of the unit Please take this into account when deciding how to vent it 1 The exhaust hose supplied with the portable air conditioner can be extended up to 48 in...

Page 13: ...mode The unit will do this automatically This mode will be sufficient for most environments If you are operating the unit in an environment with higher levels of humidity you may choose one of the ot...

Page 14: ...installed on the exhaust outlet of the unit If the adapter is not installed in this position you will need to adjust the adapters Run the excess water line into the cavity of the exhaust hose 3 Connec...

Page 15: ...and not back into the exhaust hose The unit will now automatically mist any excess water to the outside Installing the mist system in the exhaust hose ensures all of the moisture is pushed completely...

Page 16: ...e This button sets the mode The Automatic Cool Dehumidify Fan or heat indicator will appear depending on the mode you set Down This button decreases the Temperature Timer or Clock settings Clock This...

Page 17: ...e Setting This indicator shows the set temperature Fahrenheit and Celsius This indicator shows if the set temperature is in Fahrenheit or Celsius Clock This indicator shows the Clock s time The remote...

Page 18: ...the air conditioner will restart itself in its last used mode settings once power is restored The compressor will restart after 3 minutes Cooling Mode Cooling mode cools and dehumidifies the air If t...

Page 19: ...High Medium and Low Automatic Mode In Automatic mode the unit will cool dehumidify or heat certain models depending on the ambient temperature As the temperature in the room changes the mode and fan s...

Page 20: ...our clock so if it is 6 00 PM you would set the time to be 18 00 3 To save your settings press and hold the Clock button until the Clock indicator stops blinking Use the Chart below to set the 24 hour...

Page 21: ...timed hour indicator will stop blinking The unit will automatically turn off after the selected time elapses Front Panel Lights and Controls Front Panel Lights Your portable air conditioner has a fro...

Page 22: ...e pre filter 2 Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if...

Page 23: ...e set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat so...

Page 24: ...emote control is defective Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fan Remove...

Page 25: ...There are open windows and doors Close any open doors and windows There are too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The room garage may be...

Page 26: ...0 BTU COOLING CAPACITY ASHRAE 12000 BTU COLOR Silver and Grey COOLANT R410A TIMER 24 Hour DIMENSIONS HEIGHT X WIDTH X DEPTH 29 3 16 X 17 1 8 X 15 1 8 NET WEIGHT 68 Pounds Note Technical data and perfo...

Page 27: ...different standard ASHRAE that produced a higher cooling capacity output While the SACC BTU s are lower than the previous ASHRAE BTU s the construction and cooling capacity of this model s remains unc...

Page 28: ...idents acts of God vermin fire flood improper installation unauthorized service maintenance negligence unauthorized installation or modification or rental or commercial use Labor service transportatio...

Reviews: