Never connect the appliance to an unregulated gas supply line. Grills operated without a regulator 
are unsafe and will not be serviced until installed properly and safely. Unsafe operation without a 
gas regulator will void warranty of the grill.  

 

Grills operated with NG (natural gas) gas must be installed with the NG regulator supplied with 
the unit and set to 4.0" water column pressure.  

 

Grills operated with LP (liquid propane) gas must be installed with an LP regulator not supplied 
with the unit and set to 11" water column pressure.  

 

The gas valves used in the grills are preset at the factory for LP operation. Please contact your 
dealer and use a licensed contractor or installer to convert your grill to the different gas type.  

 

The self-contained LP system barbecue grill is design certified to be used with a standard 20 lb., 
12 1/4" diameter; 18" high cylinder with right handed connection threads and this is the 
maximum size LP tank to be used. The cylinder must be marked in accordance with the latest 
U.S. Department of Transportation specifications for LP gas cylinders. (DOT. CFR49 or National 
Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for the Transportation of 
Dangerous Goods) a Propane Tank with an ODP) Overfill Prevention Device) must be used at all 
times.  

Natural Gas Requirements 

 

 

Always check the Rating Plate to make sure the gas supply you are hooking up to is the 
gas type the grill is manufactured for. IMPORTANT: Never connect the grill to an 
unregulated gas supply.  

 

The installation of this appliance must conform with local codes or in the absence of local 
codes, to the national fuel gas code, ANSI Z223.1a-1998. Installation in Canada must be 
in accordance with the standard CAN/CGA- B149.2, Propane Installation Code.  

 

A licensed contractor or local gas company representative must perform all natural gas 
connections.  

 

Ensure that the service supplying the grill is fitted with a shut off valve conveniently 
positioned near the grill and giving ease of access.  

 

The grill must be isolated from the gas supply piping system by closing its individual 
manual shutoff valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than 0.5 psi (3.5 kPa).  

 

The grill and its individual shutoff valve must be disconnected from the gas supply piping 
system during any pressure testing of that system at test pressure in excess of 0.5 psi (3.5 
kPa).

 

 

 
 
 
 
 

Summary of Contents for KO-BAK1BG

Page 1: ...odor persists Keep away from your appliance and contact your gas supplier or fire department immediately WARNING Do not store or use gasoline or other flammable liquids or vapor in the vicinity of th...

Page 2: ...R SEARING BRIQUETTE SYSTEM FLAME TAMER SEARING BRIQUETTE SYSTEM ROTISSERIE KIT MOTOR FORKS OPTIONAL UPGRADE ROTISSERIE KIT MOTOR FORKS OPTIONAL UPGRADE BURNER 3 STAINLESS PIPE BURNERS BURNER 4 STAINLE...

Page 3: ...4 TOTAL COOKING AREA 920 SQ IN INCLUDES WORMING RACK FLAME TAMER SEARING BRIQUETTE SYSTEM ROTISSERIE KIT MOTOR FORKS OPTIONAL BURNER 5 STAINLESS PIPE BURNERS GAS TYPE ALL GRILLS ARE SHIPPED LP EACH S...

Page 4: ...PG 4...

Page 5: ...PG 5 NOTE CHECK WITH CITY AND FIRE DEPARTMENT FOR LOCAL BUILDING CODES A PERMIT MAY BE REQUIRED FOR OUTDOOR KITCHEN CONSTRUCTION...

Page 6: ...PG 6...

Page 7: ...PG 7...

Page 8: ...Output 12 000BTU 1Bnr Total BTU Output 24 000BTU 2Bnr Number of Burners 1 Number of Burners 2 Burner Aluminum Brass Burner Aluminum Brass Ignition SURE LIGHT Ignition SURE LIGHT Gas Type Burners are...

Page 9: ...PG 9...

Page 10: ...PG 10 BUILDING BBQ SPECIFICATIONS ALL BBQ ISLANDS MUST BE MANUFACTURED FROM NON COMBUSTIBLE MATERIAL Minimum clearance to adjacent combustible construction at 14 from sides 16 from back...

Page 11: ...n death explosion or fire GRILL INSTALLATION This gas grill must be installed in accordance with all local codes If installation is planned in an area with no local codes the gas grill must be install...

Page 12: ...ot designed for recreational vehicles and should not be installed on a boat or marine craft Protection from Weather Keep the barbecue protected from adverse weather including rain and high winds Polyv...

Page 13: ...nce continuity must exist between the appliance and an effective grounding system It is imperative that this basic safety requirement be met The manufacturer cannot be held responsible for damages cau...

Page 14: ...andards of Canada CAN CSA B359 Cylinders Spheres and Tubes for the Transportation of Dangerous Goods a Propane Tank with an ODP Overfill Prevention Device must be used at all times Natural Gas Require...

Page 15: ...eaks Perform a leak test at least once a year whether the gas supply cylinder has been disconnected or not In addition whenever the gas cylinder is connected to the regulator or whenever any part of t...

Page 16: ...hut off the gas supply to the grill and release pressure in the hose and manifold by pushing in and turning any of the control valves one quarter turn counter clockwise 8 On LP systems remove the cyli...

Page 17: ...ed at your local qualified propane dealer Once filled carefully connect the valve and make sure it is secure and not leaking With the control knobs in the OFF position turn on the cylinder valve o If...

Page 18: ...tore cylinders in a building garage or any other enclosed area Leak Testing All gas piping and connections must be tested for leaks after installation or service All leaks must be corrected immediatel...

Page 19: ...ssible Check to see if the gas line connection will be accessible when grill is installed If the gas line connection is not easily accessible when the grill is installed support the grill above counte...

Page 20: ...nce with applicable codes To guarantee the electrical safety of this appliance continuity must exist between the appliance and an effective grounding system It is imperative that this basic safety req...

Page 21: ...uisher Unit Installation Your Kokomo Grill comes pre assembled and requires very little setup We do however recommend the use of professional help during the installation of your unit as improper inst...

Page 22: ...umber _____________________________________________ Kokomo Product Registration Please take a minute to let us know what you bought This makes sure we keep you up to date and have your info ready if y...

Page 23: ...ally threaded connector LIGHTING YOUR GRILL Become familiar with the safety instructions at the front of this manual Do not smoke while lighting the grill or checking the gas supply connections Make s...

Page 24: ...knob and turn to OFF 8 It is normal to hear a popping sound when the burners are turned off Manually lighting the grill WARNING Do not use standard matches or cigarette lighters to perform match light...

Page 25: ...4 To remove burner slide burner to the rear of the grill and upward Repeat for each burner 5 Where the burner was previously located connecting to the main valve through the hole in the basin should n...

Page 26: ...nt of any liability of KoKoMo Grills under this warranty is limited to repair or replacement This warranty does not cover normal wear of parts damage resulting from any of the following negligent use...

Page 27: ...ve a leak you will see your connection start to bubble The flame in the grill is higher in the back than in the front Needs some cleaning Take the burners out remove the cotter pins that are behind an...

Page 28: ...10 Hood Handle BAK4BG 011 Y 11 Thermometer BAK4BG 012 Y 12 Cooking Plate BAK4BG 013 Y 13 Knob Bezel BAK4BG 014 Y 14 Back Infrared Burner BAK4BG 015 Y 15 Rotisserie Spit Bracket BAK4BG 016 Y 16 Rotiss...