background image

Neonatal 

Resuscitation 

Simulator–

Advance

LM-111GM

Instruction Manual

Thank you for purchasing the Neonatal Resuscitation Simulator–Advance. 
Please read this instruction manual carefully to ensure correct use of the product, 
and store it in a safe place for easy access.

Instruction manuals for the Neonatal Resuscitation Simulator-Advance in English, 
German, French, Spanish and Dutch available for download.

Manufacturer: 

KOKEN CO., LTD. 

1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN 
URL:http://www.kokenmpc.co.jp 
E-mail:[email protected] 

EU Authorized Representative for KOKEN CO., LTD.:

EC REP

MDSS GmbH
Schiffgraben 41
30175 Hannover, Germany 
www.mdssar.com

© 2021 KOKEN CO.,LTD.   C-1-1044-1-01-00

English

Summary of Contents for LM-111GM

Page 1: ...lace for easy access Instruction manuals for the Neonatal Resuscitation Simulator Advance in English German French Spanish and Dutch available for download Manufacturer KOKEN CO LTD 1 4 14 Koraku Bunk...

Page 2: ...1000...

Page 3: ...pture and leakage of battery fluid Turn off the power of the main body of the model before inserting or replacing batteries 6 Remove the batteries when storing this product Otherwise fluid may leak fr...

Page 4: ...osol lubricant silicone spray Use the prepared lubricant silicone spray after spraying a small amount onto a part of the model that does not interfere with its functioning and checking that no problem...

Page 5: ...tion 3 Handling 3 1 Installing the application 3 2 How to pair the model with the tablet PC 3 3 Explanation of screen displays 3 4 Tidying up after use 3 5 Airway management using equipment 3 6 Pulsat...

Page 6: ...s can be easily controlled on a tablet PC 2 The tablet PC can display the heart rate and SpO2 as a simulated monitor 3 This product is made of a silicone rubber that has a realistic texture and feel 4...

Page 7: ...repare four AA size alkaline batteries 5 2 Components and Configuration Components Quantity 1 Neonatal Resuscitation Simulator Advance main body Storage bag 1 1 Instruction manual this document The ki...

Page 8: ...attention to the direction of the positive and negative poles Use AA size alkaline batteries 4 3 Turn on the power of the model s main body by sliding the switch to the ON position When it is activate...

Page 9: ...lication will not start If pairing cannot be completed successfully try the pairing process again according to the following steps 1 Turn off the power of the main body of the model 2 Close the dedica...

Page 10: ...as breathing Select from a Respiratory Rate RR of 60 min or 100 min None Model does not produce any lung sounds or crying sounds SpO2 Selected SpO2 value is displayed in Monitor Mode Can select Displ...

Page 11: ...sks Monitor Mode These buttons can be used to change the SpO2 value No change in plethysmograph if SpO2 is 0 or 20 These buttons can be used to change the HR HR of the main body of the model is also c...

Page 12: ...bout remaining battery power in the model s main body When the remaining battery power in the model s main body becomes low the red LED lamp next to the power indicator light in the main body of the m...

Page 13: ...ment using equipment Ensure that you apply a lubricant silicone spray to the tip of the tube and within the oral cavity of the model when using the tracheal tube and laryngeal mask Inserting the tube...

Page 14: ...ion 5506 Notice for Radio Equipment Hereby KOKEN CO LTD declares that the radio equipment type LM 111GM is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is...

Reviews: