background image

11

3-3 Insertion of Catheterization Catheter
1.  Please open the clamp for irrigator tube and check whether or not the water leaks from the  
  simulator.

  *  When practicing the cleaning or disinfecting of the pubic area, please use water instead of  
  disinfection liquid.

2.  Please apply lubricant on the distal end of the catheter for about 4 to 5 cm and insert the    
  catheter.  

* If it is diffi  cult to insert the catheter, please check the techniques and insert it again.  In this  

  case, please remove moisture from the catheter and increase the amount of the lubricant    
  to be applied.  Also, please consider using other types of catheters (fi rm silicone catheter or 
  catheter with thinner baloon part etc).  The simulator may be broken if he catheter is forced   
  to be inserted.
  * If it is diffi  cult to insert the catheter, please use water mixed with a small amount 

(approx 5%) of surfactant (neutral detergent) as urine.

  * If the insertion of the catheter is repeated a plurality of times, water may accumulate in the 
  urethral canal.  

3.  Please check the outfl ow of the urine (water). If urine does not flow out, check the following:
  - Whether the catheter passes through the valve;
  - Whether the clamp for irrigator tube is open; and
  - The amount of water in the bag for irrigator is reduced to a small amount.

4.  

When indwelling the catheter, please inflate the balloon after inserting the catheter apart  

  from the balloon end portion by a distance equal to or greater than 4 cm. Indwelling of the  
  catheter in an intermediate of the valve causes the valve and the catheter to be broken. Please 
  provide a marker on the catheter before commencing training to ensure that the catheter tip  
  is inserted by a distance equal to or greater than 4 cm before infl ating the balloon.

4cm

Marker

Summary of Contents for LM-109FA

Page 1: ...rization and Enema Simulator Strap on type Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bu...

Page 2: ...10000...

Page 3: ...ase the insertion resistance of the catheter 5 Please do not use oily lubricant olive oil etc alcohol lubricant and lubricant containing organic solvent These may cause breakage of the simulator 6 Ple...

Page 4: ...terial resistant to tearing 17 Please do not place objects on the simulator Otherwise the simulator may be deformed 18 Please do not keep the simulator in contact with printed matter Print such as let...

Page 5: ...3 Table of Contents 1 Outline and Features 2 Components and Configuration 3 Handling Method 4 Washing and Storage Methods 5 Specifications 6 Replacement Parts Sold Separately...

Page 6: ...can be mounted on a human body or a model doll so that the practice can be performed By mounting the simulator on a human body the feeling of a patient can be simulated Also by mounting the simulator...

Page 7: ...in 3 Bladder Valve Male Female 4 O ring 5 Strap on type frame with belt 6 Female strap on type bladder tube 7 Strap on type rectum connecting connector 8 Bag for irrigator 9 Tube for irrigator 10 Drai...

Page 8: ...le strap on type bladder tube and put water into the bag for irrigator Please open a clamp fill the female strap on type bladder tube with water close the clamp and attach the bladder valve to the bag...

Page 9: ...e connect the female urethral part and the female strap on type bladder tube while adjusting their positions so that the female urethral part is fixed in the opening of the strap on type frame 5 Pleas...

Page 10: ...fix the position of the female genital skin to the strap on type frame 8 Please insert the projection of the female urethral part into the urethral canal located on the reverse side of the female geni...

Page 11: ...belt from the waist belt 2 Please wear the waist belt and adjust the adjuster according to waist size 3 Please pass the rear belt through the waist belt and fit and fix the position of the pubic area...

Page 12: ...h of the rear belt first the anus to the body and adjust the length of the rear belt first Position of the model during enema Please adjust the position of the anus on the person who or the doll that...

Page 13: ...fficult to insert the catheter please use water mixed with a small amount approx 5 of surfactant neutral detergent as urine If the insertion of the catheter is repeated a plurality of times water may...

Page 14: ...dy and adjust the length of the belt Please refer to the position of the model during enema as shown in the Figure in Section 3 2 5 on page 10 3 Please apply lubricant to the distal end of a glycerine...

Page 15: ...e slowly while holding the area of the hook and loop fastener so that it does not peel off from the female genital skin 4 Please remove the strap on type rectum connecting connector from the female ge...

Page 16: ...attention to a loss of the O ring 7 Please remove the bladder valve from the female strap on type bladder tube and drain the water in the tube 8 Please wash the female urethral part the bladder valve...

Page 17: ...genital skin After using the simulator please do not keep the female genital skin attached to the main body Please wrap it in cooking paper gauze etc put it into an attached reclosable poly bag and k...

Page 18: ...ox 23 cm Approx 13 cm Approx 11 cm Approx 0 6 kg Approx 21 cm Approx 47 cm Approx 24 cm Product name Bag for irrigator 3pcs set LM 025J Tube for irrigator 3pcs set LM 025H Product name Product No Fema...

Reviews: