background image

EGD 

(EsophagoGastroDuodenoscopy)

Simulator

LM-103

Instruction Manual

Thank you for purchasing this EGD Simulator.
Please read this instruction manual carefully to ensure correct use of the product,
and store it in a safe place for easy access. 

KOKEN CO., LTD. 

1-4-14 Koraku, Bunkyo-ku, Tokyo 112-0004 JAPAN 
URL:http://www.kokenmpc.co.jp 
E-mail:[email protected] 

©2013-2020 KOKEN CO., LTD.  C-1-1008-1-01-05

Summary of Contents for LM-103

Page 1: ...GD Simulator Please read this instruction manual carefully to ensure correct use of the product and store it in a safe place for easy access KOKEN CO LTD 1 4 14 Koraku Bunkyo ku Tokyo 112 0004 JAPAN U...

Page 2: ...may be deformed and the color may fade 5 Do not use oil based ink or paint because these will soak into the simulator and cannot be deleted 6 When transporting the simulator in the black case close al...

Page 3: ...he model after use 1 Each time after using this simulator wash the lubricating jelly inside the gastrointestinal tract with cold or hot water 2 Wipe dirt from the black case excluding the sponge parts...

Page 4: ...res 2 Components 3 Handling the Simulator 3 1 Application of lubricating jelly 3 2 Attachment of the separately sold option Simulated polyp for polypectomy LM 103A 3 3 Care for the Simulator 4 Simulat...

Page 5: ...ransoral and transnasal insertion can be practiced 3 For the transnasal insertion the difficulty setting of insertion can be changed by placing the nasal septum pieces to deviate to the right or the l...

Page 6: ...ce 5 Main head piece 6 Duodenum piece 7 Nasal septum deviated to the left 8 Nasal septum deviated to the right 9 Simulated polyp for polypectomy conduction cable 10 Stand 11 Simulated polyp xture 13 H...

Page 7: ...Cardiac connector Nasal septum piece Hypopharynx piece 6 3 3r r 8 HZ qu H HZ Z EN K 3 K z A K 3 K 1 4 HZ A 6 3 Usage Before using this simulator apply lubricating jelly to each piece Use any endoscopi...

Page 8: ...l septum piece is available as both a right and left deviation type Select one and apply the lubricating jelly Then attach it to the main head piece Right deviation Left deviation 7 The nasal septum p...

Page 9: ...icating jelly to the hypopharynx piece attach it to the main head piece Put the half head piece back on the main head and secure them with Velcro tape Apply lubricating jelly to the inside of the esop...

Page 10: ...ing rod Pyloric connector Pyloric fixing rod Apply lubricating jelly to the inside of the esophagus piece Insert lubricating jelly into the esophagus piece from the hypopharyngeal and cardiac ends and...

Page 11: ...emoving the stomach and duodenum piece from the pyloric fixing rod Pyloric connector Pyloric fixing rod 9 To remove the stomach remove the pyloric connector that connects the stomach to the duodenum p...

Page 12: ...e cardiac and pyloric connectors and spread it to the entire inner side of the main stomach by kneading it from the outside When kneading it be careful not to dig your nails into the piece It may be d...

Page 13: ...duodenum piece by kneading it from the outside When kneading it be careful not to dig your nails into the piece It may be damaged Attach the pyloric connector Join the ease points of the connectors to...

Page 14: ...y When not covered the general location of the endoscope can be seen from the outside of the simulator with the endoscope light When covered the endoscopic light cannot be seen from the outside and tr...

Page 15: ...roperty of the preservative and the polyp Keep the storage liquid out of the eyes and mouth Attachment of the return electrode Stick the plate side of the simulated polyp for polypectomy conduction ca...

Page 16: ...ed polyp fixture on top of the ba e plate of the stand Insert the simulated polyp for polypectomy into the ring side of the simulated polyp for polypectomy conduction cable Insert the simulated polyp...

Page 17: ...hard case for the body side pull the cord from the cutout in the stand The cord is not included Practicing resection is possible under the same output of the high frequency ablation instrument as with...

Page 18: ...ot to dig your nails into the pieces They may be damaged 15 3 3 Care after use Clean the EGD simulator each time after it was used Cleaning should be done by the following steps Remove each piece from...

Page 19: ...exposed to direct sunlight After the pieces have dried attach the main head to the stand and then set each piece Attach by fitting the hole at the bottom of the main head to the rod sticking from the...

Page 20: ...ble 1 pc 1 pc Stand Simulated polyps for observation Yamada classi cation types I to IV 1 set Simulated polyp xture 1 pc Hard case for the head side 1 pc 1 pc Hard case for the body side 1 pc Product...

Reviews: