KOHTECT 107VF User Manual Download Page 4

Overview 

The  107VF  Vibration  Analyzer  (Device,  Analyzer)  is  a  compact  yet 
powerful,  vibration  analyzer  designed  to  measure  overall  vibration 
parameters,  FFT  spectrum  analysis  of  the  rotating  machinery, 
immediate  evaluation  against  ISO  10816  standard,  condition 
monitoring  by  route  based  measurements  and  data  collection.  Route 
files and data files exchange via email makes it ideal for data collection 
at  remote  sites.  Simple  in  use,  with  free  firmware  upgrades,  comes 
with data management and reporting software.    

Kit Content 

The 107VF kit includes:

 

 

 

107VF display unit; 

 

AC102-1A  accelerometer,  incl. 
cable  1.8m,  magnet  for  curved 
surface mount; 

 

USB wall charger; 

 

USB cable; 

 

CD with ConSpect software and 

User’s Manual;

 

 

Carry case. 

 

Specifications 

Inputs

 

  IEPE  or  charge  type  accelerometers  with  known  sensitivity, 

switchable.  Optical  RPM  transducer  with  IR  pyrometer  sensor 
(optional) 

AD conversion

 

 24 bits 

Frequency range

 

 

1…10000 Hz

 

Summary of Contents for 107VF

Page 1: ...107VF Vibration Analyzer User s Manual 2018...

Page 2: ...asurement functions 6 Operation 6 Keyboard 6 Settings 7 Date Time 7 Sensors 8 Units 8 Auto OFF 8 Vibration 9 Vibration measurement settings 10 Taking measurements 11 To save measurements 12 Route base...

Page 3: ...s could cause personal injury or death The Analyzer could not be used in potentially explosive environments Take measures to prevent cables and straps become entangled by rotating part of machines at...

Page 4: ...email makes it ideal for data collection at remote sites Simple in use with free firmware upgrades comes with data management and reporting software Kit Content The 107VF kit includes 107VF display un...

Page 5: ...cy 0 5 0 60 C 1 40 120 C 2 70 180 C 4 70 380 C Tachometer measurement range 10 200 000 rpm Accuracy 0 1 and 1rpm FFT spectrum resolution 400 800 1600 lines Data storage 4GB micro SD card PC interface...

Page 6: ...s speed of rotation by means of contactless optical sensor The measurement result is displayed in RPM and Hz IR thermometer contactless measurement of object temperature The measurement result is disp...

Page 7: ...to OFF delay setup Date Time Use arrow keys to set date Hold then press or for month decrement increment Confirm by when correct date is set Use keys to set minutes and hours Use key to switch focused...

Page 8: ...or charge type sensors to choose from Confirm choice by key Type S N and Sensitivity fields are editable Use key to choose field to edit Then use arrow keys to edit the field value Units This option i...

Page 9: ...measures vibration Acceleration Velocity and Displacement In ISO 10816 mode measurement result is compared to the built in table of vibration severity grades according to ISO 10816 3 Use keys to choos...

Page 10: ...per frequency limit Can be set from 200 to 10000 Hz for Acceleration from 200 to 5000 Hz for Velocity from 200 to 800 Hz for Displacement FFT lines FFT spectrum resolution Can be set to 400 800 1600 l...

Page 11: ...running Use key to toggle FFT spectrum waveform display Press key to stop resume measurement When measurement is stopped Press key for Options Save to save measurement data Press key to proceed Forma...

Page 12: ...en press key save measurement Device writes two files at a time FFT spectrum file and waveform file Device remembers path to the last written files To create new folder press key Date time stamp is us...

Page 13: ...and download it to the device Go to Documents menu move cursor to the route file and press key Use to browse route points Attach sensor at the measurement point and press key Device takes measurement...

Page 14: ...2 only Connect optical probe to the device Enter Tachometer menu Aim optical probe to the rotating machine part with attached reflective tape Press key to start stop measurement Device displays measur...

Page 15: ...Thermometer 107VF T2 only Connect optical probe to the device Enter Thermometer menu Aim optical probe to the machine Press key to start stop measurement Device displays measurement result in C and F...

Page 16: ...NPP KOHTECT 73 V Lomonosova str of 38 Kiev 03189 Fax 38044 2577338 www koh tect com...

Reviews: