107VF
Vibration Analyzer
User’s Manual
2018
Page 1: ...107VF Vibration Analyzer User s Manual 2018...
Page 2: ...asurement functions 6 Operation 6 Keyboard 6 Settings 7 Date Time 7 Sensors 8 Units 8 Auto OFF 8 Vibration 9 Vibration measurement settings 10 Taking measurements 11 To save measurements 12 Route base...
Page 3: ...s could cause personal injury or death The Analyzer could not be used in potentially explosive environments Take measures to prevent cables and straps become entangled by rotating part of machines at...
Page 4: ...email makes it ideal for data collection at remote sites Simple in use with free firmware upgrades comes with data management and reporting software Kit Content The 107VF kit includes 107VF display un...
Page 5: ...cy 0 5 0 60 C 1 40 120 C 2 70 180 C 4 70 380 C Tachometer measurement range 10 200 000 rpm Accuracy 0 1 and 1rpm FFT spectrum resolution 400 800 1600 lines Data storage 4GB micro SD card PC interface...
Page 6: ...s speed of rotation by means of contactless optical sensor The measurement result is displayed in RPM and Hz IR thermometer contactless measurement of object temperature The measurement result is disp...
Page 7: ...to OFF delay setup Date Time Use arrow keys to set date Hold then press or for month decrement increment Confirm by when correct date is set Use keys to set minutes and hours Use key to switch focused...
Page 8: ...or charge type sensors to choose from Confirm choice by key Type S N and Sensitivity fields are editable Use key to choose field to edit Then use arrow keys to edit the field value Units This option i...
Page 9: ...measures vibration Acceleration Velocity and Displacement In ISO 10816 mode measurement result is compared to the built in table of vibration severity grades according to ISO 10816 3 Use keys to choos...
Page 10: ...per frequency limit Can be set from 200 to 10000 Hz for Acceleration from 200 to 5000 Hz for Velocity from 200 to 800 Hz for Displacement FFT lines FFT spectrum resolution Can be set to 400 800 1600 l...
Page 11: ...running Use key to toggle FFT spectrum waveform display Press key to stop resume measurement When measurement is stopped Press key for Options Save to save measurement data Press key to proceed Forma...
Page 12: ...en press key save measurement Device writes two files at a time FFT spectrum file and waveform file Device remembers path to the last written files To create new folder press key Date time stamp is us...
Page 13: ...and download it to the device Go to Documents menu move cursor to the route file and press key Use to browse route points Attach sensor at the measurement point and press key Device takes measurement...
Page 14: ...2 only Connect optical probe to the device Enter Tachometer menu Aim optical probe to the rotating machine part with attached reflective tape Press key to start stop measurement Device displays measur...
Page 15: ...Thermometer 107VF T2 only Connect optical probe to the device Enter Thermometer menu Aim optical probe to the machine Press key to start stop measurement Device displays measurement result in C and F...
Page 16: ...NPP KOHTECT 73 V Lomonosova str of 38 Kiev 03189 Fax 38044 2577338 www koh tect com...