background image

ROUGHING-IN

UNIT: mm

438

478

1081

147

190

0-300

180

230

290

25

35

337

155-200

962

48-58

0-48

RECOMMENDES TOOLS  AND MATERIALS 

所需工具及材料

开口/活动扳手
美工刀
锉刀
钢锯
冲击钻
水平尺
十字螺丝刀
绝缘胶布
卷尺
生料带
电工套管
润滑油

SENSOR SPECIFICATIONS

Open end/adjustable Wrenches

Knife

File

Hacksaw

Masonry

Level

Screw driver

Insulation tape

Tape measure

Seal tape

Bushing

Lubricant

-2-

1359749-T01-A

6.0L

6.0L

5.0L

3.0L

3.5L

3.5L

1 ~45

24

注:红外发射角度为水平向下

10°

K-6281T-VE2-NA

K-6281T-VES2-NA

K-6281T-ESS-NA

大档水量
小档水量

220V ~,  50/60HZ

: 1 ~55

距感应窗口

70cm

以内(沿发射角度方向)

5~8

Model

Liter per flushing

6.0L

6.0L

5.0L

3.0L

3.5L

3.5L

K-6281T-VE2-NA

K-6281T-VES2-NA

K-6281T-ESS-NA

Large flushing volume

Small flushing volume

Power

Temperature

Sensing distance

220V ~,  50/60Hz

5~8 seconds after user leave
Auto flush once every 24h if unused

Environmental temperature: 1  ~55 

Water temperature: 1  ~45

Within 70cm from sensing window

(along the direction of transmitting angle)

Flushing delay
Protective flushing

NOTE

: The infrared transmitting angle is 10° downwards.

K-6281T-DNSW-NA

K-6281T-DNW-NA

K-6281T-VABW-NA
K-6281T-RES-NA

K-6281T-VLS-NA

K-6281T-DNSW-NA

K-6281T-DNW-NA

K-6281T-VABW-NA
K-6281T-RES-NA

K-6281T-VLS-NA

Summary of Contents for VIA K-20629T-BW

Page 1: ...K 20630T BW K 19720T W 200 K 20007T VABW K 4141T 2P 300 K 20645T BW K 19720T W 300 K 20010T VABW K 4141T 2P 300 K 20648T BW K 19720T W 300 K 4179T VABW K 4141T 2P 100 K 20649T BW K 19720T W 100 K 628...

Page 2: ...1 Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2013 This product complies with GB 25502 2017 Water Efficiency Grade 1 140mm 50mm 1 ASME A112 19 2 2...

Page 3: ...SKU of faceplate INSTALLATION Fig 2 2 1 1 2 3 2 SET THE SPACING OF THE BOWL After you install the tank be careful to set the spacing of set aside the length for carrier studs and tighten nut The bowl...

Page 4: ...a little after it is installed to prevent water storage See Fig 4 See Fig 5 3 1 2 3 4 4 5 Fig 4 4 Fig 5 5 Inlet Outlet 1 4 INSTALL THE NEW TOILET 1 Install the accessory kit into the installing hole...

Page 5: ...ners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for...

Page 6: ...tallation with spares not provided by Kohler Function Explanation 2010 Copyright Kohler China Ltd 2010 1955 200444 Advantages Of Touchless In wall Tank Advanced tank spares flush volume refer to senso...

Page 7: ...r per flushing 6 0L 6 0L 5 0L 3 0L 3 5L 3 5L K 6281T VE2 NA K 6281T VES2 NA K 6281T ESS NA Large flushing volume Small flushing volume Power Temperature Sensing distance 220V 50 60Hz 5 8 seconds after...

Page 8: ...n in Fig A Tighten the bolts with medium Allen key as shown in Fig B adjust the height of the adjustable bracket in compliance with customer s requirements and then tighten the nut with hex pan Based...

Page 9: ...e pipe to the drainage hole as shown 4 3 NOTE Ensure the tank to remain level 3 ConnectingPipe WaterPipe Drainage Hole Drainage Pipe A B 1 2 Spanner Adjustable Bracket Hex Pan Tighten Loosen Hexagonal...

Page 10: ...nnector and output connector or product may be damaged 6 16 20 AC AC220V B Installation of Rectangular Shield Knife Cover 2 Install the rectangular shield in the block screen of the tank and tighten t...

Page 11: ...liminate unwanted rectangular shield with a sharp knife 6 Rectangular Shield Big Filtration Cap Small Filtration Cap Big Filtration cap Small Filtration cap Long Screw 3 Fix the motor wire panel conne...

Page 12: ...Pipe Outlet Pipe C Installation of Toilet 1 Install the inlet pipe and outlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pencil and reserve ap...

Page 13: ...tration and use a spirit level to ensure the lavatory to remain level 5 Spirit Level 4 48mm 58mm of the long screw shall be reserved outside the wall as shown in the illustration If the long screw out...

Page 14: ...the requirements of installation dimensions And make sure the long screw would not bump any other parts D Installation of Cover 2 Fix the adjustable board to the wall by tightening the lock nut as sh...

Page 15: ...nect the connectors and take down the cover NOTE Before disassembly please close the input valve firstly Cover Lock Cover AdjustableBoard a b 5 As illustrated make the locker of panel aim at locker of...

Page 16: ...table board as shown 4 3 Tighten the locknut to the marked position of OPEN to take out the adjustable board 3 OPEN Locknut Adjustable Board Adjustable Board Long Screw 2 2 Loosen the long screw as sh...

Page 17: ...d take them out 5 String Screw 5 Take motor wire out of the soft belt release the two screws that locked the box NOTE Screws will not quit easily just feeling that the screw is threaded out is enough...

Page 18: ...rasp the top of the inlet valve and push back 9 Pipe Top Inlet Valve 10 Hole the pole bracket with your hands as shown Then take out the pole bracket by pulling it 10 Pole Bracket 8 8 Remove the lock...

Page 19: ...ck on or off by hand Move the lock on and open the cover then the outlet valve can be loosen Note 11 Open Lock A Wash Filtration Net Close corner valve first then loosen and take out the tighten nut a...

Page 20: ...tank by adjusting the control pole Turn the control pole counterclockwise to lower down the floating box and reduce the water level of the tank Turn the control pole clockwise to hoist the floating b...

Page 21: ...with clean water 1 Long screw is tighten too far 2 Pole lock is not locked tight enough with the reversed lock 1 Loosen the long screw make sure the sign the long screw accords with the hole on refer...

Page 22: ...4 5 6 7 8 9 10 11 12 13 4 5 6 7 8 9 10 11 12 13 17 1359749 T01 A...

Page 23: ...zardous materials used in this product The product service life for environment protection is 10 years Kohler Company will specify product service life based on product characteristics The product ser...

Page 24: ...10 10 GB T 26572 GB T 26572 Pb Hg Cd Cr VI PBB PBDE 19 1359749 T01 A...