background image

G1/2˝

G1/2˝

233

335

126

98

514

31~40

76

78

232

50

84

35

68

    

  

41.5

302
240
150

Ø42

40

Ø37

29~38

46

149

51×51

49

60

53

   

                                                                         

1418848-2A-C          

                                                                                                                                          7 

  

   

                                                                          

1418848-2A-C           

                                                                                                                                         2

  

ROUGH-IN DIMENSIONS

The Finished Floor

Recommended Height

1100~1200

Recommended Height

2100~2200

Showerhead

Stop pin

Notch

2. Remove the screw(52) and adapter spline(53), and 

then unscrew the nut(55) and stopper(54). Remove 

the cartridge cautiously. Clean the thermostatic 

cartridge by soaking it in warm vinegar. 

2

Cartridge

3

Notch

Stop pin

5

Groove

Round mark

6

27

50

51

52

53

49

52

53

54

55

1

Number 37

27

50

51

49

3. After cleaning, install the “stop assembly” back on 

the cartridge, adjust the stop pin into the notch.

4. Install the assembly cartridge and stop in the body, 

adjust the stop pin into the notch.

5. 

NOTE: 

Do not turn the cartridge when reinstalling it. 

If you turned it accidentally, you should adjust it and be 

sure that the round mark is correctly in line with the 

groove, or readjust as per the steps of verification and 

setting.

6. Install the adapter spline(without turning the spindle). 

Ensure the indicator line on the adapter spline align with 

the indicator line on the stopper. Tighten the screw(52) 

with a screwdriver. Install the temperature handle(49). 

Ensure the number 37 on temperature handle is upward 

vertically(After assembly, it could not be turned counter-

clockwise if not pushing the button). Tighten the screw 

(50) with 2.5mm hex wrench(27). Insert the plug(51).

Clear the Thermostatic Cartridge

 

Very hard water can obstruct the filters on the thermostatic cartridge and reduce the water flow. Please clean the cartridge 

as follows: Shut off the water supply of the faucet and turn on the water flow valve, then proceed to remove the cartridge. 

The cartridge is sensitive part, please be careful.

1. Before your action, make sure the number 37 on the 

temperature handle is upward vertically(It could not be 

turned counter-clockwise if not pushing the button). 

Remove the temperature handle(49).

Indicator line

Upward 

horizontally

4

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. 

Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the 

finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

Summary of Contents for URBANITY 25717T-9

Page 1: ...way from heater or it may become damaged and cause injury to the user OPERATION CONDITION 25717T 9 Recessed Thermostatic Dual Shower Faucet Multifunction Showerhead The temperature is set by slowly turning the temperature handle right hand handle For safety reasons there is a stop that limits temperature to 37ºC To get a higher temperature push the button on right handle and continue turning the t...

Page 2: ...apter spline align with the indicator line on the stopper Tighten the screw 52 with a screwdriver Install the temperature handle 49 Ensure the number 37 on temperature handle is upward vertically After assembly it could not be turned counter clockwise if not pushing the button Tighten the screw 50 with 2 5mm hex wrench 27 Insert the plug 51 Clear the Thermostatic Cartridge Very hard water can obst...

Page 3: ... spline 53 Under the normal condition of water flow slowly turn the temperature selector Always in the same direction from the cold water position until water temperature reaches 37ºC If the temperature goes over 37ºC go back to the cold setting and reset it When the temperature is stable do not turn the cartridge spindle Install the adapter spline Ensure the indicator line on the adapter spline a...

Page 4: ... with one waterpipe not provided As figure 6 shown remove the screws 17 from the protector 8 with screwdriver not provided and pull it out Remove the connectors 18 with 8mm hex wrench take off the filter washers 19 Flush water supply pipes for about one minute to remove any debris Insert two G1 2 plugs not provided into the connections 20 Apply water pressure 8bar test on the product Check for lea...

Reviews: