1387024-2A-E
5
1387024-2A-E
4
Slot
Protector cap
Restrictor
23
25
26
27
24
Clear the Filter
The filters can protect the faucet, but it may get obstructed and
reduce water flow after a long time of use. If this happens, turn off
the water supply, uninstall the shower column.
Take out the plugs(17). Unscrew two screws(4) with 3mm hex
wrench(3) to uninstall the faucet. Take out the filters by hand.
Clean the filters by soaking them in warm vinegar. Reinstall them
in turn.
CARE AND MAINTENANCE
INSTALLATION CHECKOUT
Number 37
Ensure that all connections are tight, the switch buttons are not
turned on. Turn on the water supply. Run water through the valve.
Check for leakage. Repair as needed.
Press the buttons separately. Check whether all connections and
water flow are well.
Shut off the faucet.
Verification and Setting
Make sure that the water feeds of the faucet have reach the
highest temperature by running the water sufficiently. When the
number 37 on the temperature handle(28) is upward vertically,
the water temperature should be within a range of 36ºC and 38ºC,
as measured by a thermometer. If not, the installer can adjust the
setting. Proceed with the setting as follows:
Remove the plug(30). Take out the screw(29) with 2.5mm hex
wrench(26) to uninstall the temperature handle(28). Remove the
screw(31) with a screwdriver. Remove the adapter spline(32).
Under the normal condition of water flow, slowly turn the
temperature selector(Always in the same direction) from the cold
water position until water temperature reaches 37ºC. If the
temperature goes over 37ºC, go back to the “cold” setting and
reset it. When the temperature is stable, do not turn the cartridge
spindle. Install the adapter spline. Ensure the indicator line on the
adapter
spline align with
the indicator line on the stopper. Tighten
the screw(31) with a screwdriver. Install the temperature handle.
Ensure the number 37 on the temperature handle is upward
vertically(After assembly, it could not be turned counter-clockwise
if not pushing the button). Tighten the screw(29) with 2.5mm hex
wrench. Insert the plug(30).
Install the Showerhead
Before installation, install the restrictors if needed. Install the
restrictors into the connectors on the showerhead(23).
Remove the protector caps from the tube kit outlet(24) and
showerhead separately.
Insert the showerhead to the tube kit
outlet as shown.
Insert the pin(25) into the slot. Tighten the screw(27) with 2.5mm
hex wrench(26).
WARNING:
Ensure the screw is tightened to avoid the product
falling and personal injury.
Install the Body
To perform installation, installer must provide G1/2
″
female supply
fittings(1), spaced 150mm apart, horizontally and vertically to the
finished flat wall. Flush the water supply pipes thoroughly to
remove any debris.
NOTE:
Apply water pressure test on water supply pipes before
installing the connectors(2).
Apply enough tape or suitable sealant on threads of connectors.
Install two connectors into the hot and cold supply pipes.
Adjust the center-to-center distance between the connectors to
150mm horizontally. They should extend 36~45mm beyond the
finished wall.
NOTE
: Rotate the C-rings with their openings
downward, and pull forward the C-rings to clamp the connectors.
Adjust two screws(4) with 3mm hex wrench(3). Install the faucet
body to the connectors until it is against the finished wall.
Pre-tighten two screws with 3mm hex wrench(The screws should
contact with the connectors through the C-rings’ openings).
Tighten them after completing the installation of shower column.
INSTALLATION
Install the Shower Column and Handshower
Rehearse the shower column kit installation for the base
mounting location determination.
1. Remove the protector cap from the connecting pipe(5). Insert
the shower column onto the connecting pipe firmly to the end.
2. Put the mounting base(6) into the column insert(7)(Make sure
the shower column is vertical. Check whether it is vertical with the
level(8)). Mark the location of the mounting base with a pencil.
3. Uninstall the shower column. Mark the holes of the mounting
base with a pencil.
Install the mounting base.
1. Drill Ø10mm holes(The depth is not less than 45mm) on the
marks.
2. Insert the anchors(9) into the holes. Tighten the screws(10) with
a screwdriver in order to secure the mounting base.
Install the shower column.
1. Slide the shower bracket(11) into the shower column. Install
the shower column to the mounting base(6) and connecting
pipe(5) firmly to the end.
2. Tighten the screws(14) and washers(13) with 4mm sphere hex
wrench(12). Install the cover(15). Put the cap(16).
3. Ensure the upper surface of the faucet body is horizontal with
the level(8). Tighten two screws(4) with 3mm hex wrench. Press
the plugs(17) into the faucet.
Install the handshower.
1. Remove the protector cap from the connector(21)
.
Put the
screen washer(18) into the shower hose(19). Connect the
connector(21) and handshower(20) with hose.
NOTE
: Do not over
tighten.
2. Install the check valve(22) into the handshower if needed.
3. Hang the handshower on the shower bracket(11).
26
28
29
30
31
32
Upward
horizontally
Spindle
Indicator line
4
3
17
Filter
36~45mm
4
3
Cold
Hot
Cold
Hot
1
2
150mm
Opening
downward
Screw
C-ring
5
8
14
13
12
10
6
9
7
16
Protector cap
Protector cap
15
4
3
21
11
22
19
20
18
17