background image

1-1/4"

Notes

Required Electrical Service

Measure your actual product for rough-in details.

One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).

Install this product according to the installation
instructions.

The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.

240 V, 15 A, 50/60 Hz

Blower, Heated

Surface:

Technical Information

If relocating the blower motor, do not relocate or
alter the PVC tee or coiled flexible tubing

All product dimensions are nominal.

Three-wall alcove

Installation:

connected to the blower. Follow the blower
relocation instructions exactly. Provide access
for servicing the blower.

Left

Drain location:

42-3/8" x 20" (1076 mm x 508 mm)

Basin area, bottom:

ADA compliant when installed to the specific
requirements of these regulations.

54-3/8" x 24-5/16" (1381 mm x 618 mm)

Basin area, top:

106 lbs (48.1 kg)

Weight:

44 lbs/ft² (214.8 kg/m²)

Minimum floor load:

15-1/16" (383 mm)

Water depth:

59.8 gal (226.4 L)

Water capacity:

Blower: 240 V, 5 A, 50/60 Hz
Heated Surface: 240 V, 0.5 A, 50/60 Hz,
65 W

Electrical component

rating:

Variable

Blower speed:

2-1/2" (63 mm)

Minimum flat for door:

1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to 

www.kohler.com

.

9-7-2019 05:55 - US/CA/MX

Underscore

®

 Rectangle

5' BubbleMassage

 Bath

K-1167-GLW