1. How To Install The Faucet

To perform installation, installer must provide G1/2

˝ 

female supply fittings, spaced 150mm 

apart and horizontally. The supply fittings should be vertical and not beyond the finished wall. 

Hot supply pipe must be located on the left.

Install the two offset connectors(1) into the hot and cold supply pipes. Use appropriate thread 

sealants or thread tape on pipe threads. Adjust the center-to-center distance between the 

connectors to 150mm and horizontally. They should extend 40 to 45mm beyond the finished 

wall. Thread the escutcheons(2) onto the connectors until they are against the finished wall. 

Put the washers(3) into the nuts(4), thread the nuts to connectors. Tighten the nuts with strap 

wrench or soft cloth between product and regular wrench.

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. Many 

cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the finish and are 

not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

Ensure that all connections are tight. Ensure that the handles are in the off position. 

Turn on the drain and main water supply, and check for leaks. Repair as needed.

INSTALLATION CHECKOUT

OPERATION INSTRUCTIONS

CARE AND MAINTENANCE

2. How To Install The Shower Column

Select a location in vertical wall to install shower column according

to rough-in dimensions.

Drill the lower hole as anchors(5) diameter and lower base(7-1) 

position in the finished wall (

NOTE:

 The arrow in the base is 

upward). Press anchors into the hole, secure the base by the 

screws(6). 

Rehearse the slide bar kit(8) installation for the upper base(7-2) 

mounting location determination. Slide the tube joint(9) onto the 

slide bar kit, and connect them to the base(

NOTE:

 The arrow in 

the base is up). Install the screws(11) into the tube joint with the 

hex wrench(10), and tighten them.
Place the slide bar and the body 

against the finished wall. Connect 

the lower base and the diverter body 

kit(12). Position and tighten them by 

hex wrench. Mark the hole of upper 

base(7-2) with a pencil. Uninstall the 

slide bar kit and tube joint.

(

NOTE:

 Don’t lose the screws.)

Drill holes on the mark. Press the 

anchors into the holes. Secure the 

upper base(7-2) by the screws. Install 

the tube joint(9) to the base(7-2) and 

tighten them by screws. Reinstall the 

slide bar kit with escutcheons(13) 

to the bases. Tighten the screws with 

the hex wrench. Screw the 

escutcheons with the bases until 

against the finished wall.

Install the tube kit(14) into the slide 

bar kit. Install the nut(15) onto the 

tube kit with soft cloth between 

internal hole of the nut and the 

tube kit. Then screw the nut onto 

the slide bar kit with strap wrench 

or soft cloth between the nut and 

regular wrench.

3. How To Install The Handspray & Hose

Remove the guards on the outlet connectors of 500mm 

length hose(17). Connect the outlet(16) to the connector

(18) with the hose(17), and tighten.

Turn the diverter handle(19), run hot and cold water for 

about one minute to remove any debris.

Remove the guards on the outlet connectors of 1500mm 

length hose(20). Tighten the shorter connector(20-1) of the 

hose(20) to the connector(21). Put the restrictor(22) into the 

handspray(23) inlet if needed. Tighten the handspray to the 

longer connector(20-2) of the hose. 

4. How To Install The Showerhead

Turn the diverter handle(19), run hot 

and cold water for about one minute 

to remove any debris before the 

showerhead(24) is installed. 

Take out the washer(26) and install 

the restrictor(25) into the showerhead 

as shown if needed, reinstall the 

washer. Tighten the showerhead onto 

the tube kit outlet with strap wrench.

Stopper Adjustment

If the flow can’t meet the demand, it can be adjusted(Fig.1). Uninstall the handle 

kit and adjust the position of stopper. Turn the counter-clockwise to increase the 

flow rate; turn clockwise to decrease the flow rate.

NOTE: 

When you reinstall the handle, make sure the flow valve in the “close” 

position, the button of water flow handle should be aligned with the 37 mark. 

Tighten the screw. Put on the handle plug.

Verification And Setting

Make sure that the water feeds of the faucet have reach their highest temperature 

by letting the water run sufficiently. With the selector in position 37ºC, the 

temperature of the water coming out of the faucet must be within a range of 36ºC 

and 38ºC, as measured by a thermometer. If this is not the case, the installer can 

adjust the setting. Proceed with the setting as follows: Remove the handle plug. 

Untighten the screw with the screwdriver, remove the handle kit. With the faucet 

on “cold” normal water flow, slowly turn the temperature selector(always in the 

same direction) until water at 37ºC is obtained. If the temperature goes over 38ºC, 

go back to the “cold” setting and set again. When the temperature is stabilized, 

without turning the cartridge spindle, make sure the reference mark of the 

temperature handle aligned with the number 37. Tighten the screw, put on the 

handle plug(Fig.2).

After cleaning, install the “stop assembly” 

back on the cartridge, adjusting the stop pin 

into the notch(Fig.4). Install the assembly 

cartridge and stop in the body, adjusting the 

stop pin into the notch(Fig.5).

NOTE:

 

Do not turn the cartridge when 

reinstall it. If you turned it without carefully, 

you should adjust it and be sure that the 

round mark is correctly in line with the 

groove(Fig.6), or readjust as per the steps 

of verification and setting.

Install the temperature selector(without 

turning the spindle) lining the number 37 

with the reference mark. Tighten the handle 

with the screw. Put on the handle plug.

Very hard water can obstruct the filters 

proteccting the thermostatic cartridge 

and reduce the flow of water. Please 

clean the cartridge as follows: Shut off 

the water supply of the faucet and open 

the water flow handle, then proceed to 

remove the cartridge. The cartridge is 

sensitive, please be careful.

Mark sure the reference mark is aligned 

with number 37 before your action. 

Remove the handle kit(Fig.1), unscrew 

the nut and stopper(Fig.2). Removing the 

cartridge cautiously(Fig.3). Clean the 

thermostatic cartridge by soaking it in 

warm vinegar. 

The filters(27) protecting the 

faucet device may get obstructed 

and reduce water flow. When this 

happens, unscrew the bushes(28, 

left thread) by a wrench(12mm) 

and take out the nuts(29), filters 

(27) and the check valves(30) 

after removing the faucet. Clean 

the filters by soaking them in 

warm vinegar. Reinstall them as 

the figure. (

Note:

 Check valves 

should reinstall as original 

orientation).

2

1

150mm

40~45mm

4

Hot

Cold

3

5

6

11

7-2

13

5

6

11

7-1

13

12

15

14

9

10

8

24

25

26

20

17

16

22

23

20-2

20-1

18

19

21

Increase the flow

Decrease the flow

Fig.1

Fig.2

Fig.1

Fig.2

Fig.3

Fig.4

Fig.5

Fig.6

27

28

30

29

Stop assy

Cartridge

Cartridge

Notch

Cartridge and 

stop assy

Number 37

Reference mark

Spindle

Stop pin

Stopper

Stopper

Plant setting position

Stop pin

Groove

Round mark

Notch

Reviews: