TO REMOVE EXISTING TOILET

Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.

(

)

INSTALLATION

Fig.#2

2

Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.

if the new toilet is not

installed immediately, temporarily stuff
a rag into the closet flange.

NOTICE:

T

NOTICE:

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.

Closet Flange

67mm;

229mm

200mm

Fig.#3

3

TO INSTALL SUPPLY
SHUT-OFF VALVE

Install the supply shut-off valve so it is
229mm above the finished floor line,
and 200mm to the left of the closet
flange centerline.

The centerline of the supply shut-off
valve outlet should extend 67mm from
the finished wall. Install the supply
shut-off valve with the outlet vertical.

Supply Shut-Off Valve

Closet Flange
Centerline

200

305/400

229

10mm

5

TO INSTALL BOWL

Position the template and align with drain hole.

Mark down the position of foot and 5 holes.

Drill holes on ground with the drill of 10mm (3/8"), then insert
anchor to holes.

CAUTION:

Please make sure there is no water pipe or spool

under the 5 holes to be drilled.

Fig.#4

4

Fig.#5

5

Drain Hole

3/8

10mm

Install brackets.

Fig.#6

6

1397913-T01-B

Summary of Contents for S-TRAP K-23188T-HC

Page 1: ...C Family Care Skirted 1PC 400mm W O Seat K 23189T HC W O 305mm K 23188T ITHC 400mm K 23189T ITHC 305mm K 23188T HC 400mm K 23189T HC 1 Copyright Kohler China Investment Co Ltd 2020 2020 No 2 KOHLER ROAD SANSHUI CENTRAL INDUSTRIAL PARK LEPING TOWN SANSHUI DIST FOSHAN GUANGDONG PRC POST CODE 528137 2 528137 8 MENGSHAN RD ECONOMIC DEVELOPMENT ZONE OF HUANTAI ZIBO SHANDONG CHINA 256410 8 256410 NO 1 K...

Page 2: ...ied The stop valve and wax ring are not supplied NOTICE 254mm 305mm 60cm 8mm T 2 10mm WARNING Risk of personal injury or product damage WARNING Risk of external leakage Handle vitreous china products very carefully Vitreous china can break and chip if you overtighten bolts and nuts The fill valve nut has been factory tightened to design specifications If re tightening is required wrench tighten on...

Page 3: ...s not responsible for any damage caused by installation with the use of cement Closet Flange 67mm 229mm 200mm Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 229mm above the finished floor line and 200mm to the left of the closet flange centerline The centerline of the supply shut off valve outlet should extend 67mm from the finished wall Install the supply shut...

Page 4: ...ust use the toilet installation gasket ring not supplied to seal the area where the waste pipe contacts the construction section to avoid leakage Thread the supply hose onto the fill valve shank See Fig 9 9 Fig 9 9 Install the toilet seat according to the seat manufacturer s installation instructions See Fig 10 10 Fig 10 10 Insert the inlet hose of the toilet and the power line and inlet hose of t...

Page 5: ...rtain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Make sure water supply is off Remove valve END by rotating it 1 8 turn counterclockwise While holding a container over the uncapped VALVE to prevent splashing turn w...

Page 6: ...e container and recheck the connection of the water supply pipe Fig 18 18 2 Function of the selection switch 2 Switch is on Water flows through the toilet bowl cleaner container and carries water therein into the toilet Switch is off Water directly flows into the toilet without passing through the toilet bowl cleaner container 3 Toilet bowl cleaner replacement 3 Lift the tank cover and move it asi...

Page 7: ... it is completely dissolved to guarantee the effect Use the free toilet bowl cleaner inside or replace with similar products less than the size of 70 H 70 W 25 H mm 4 15 70 70 25 mm 7 PUSH BUTTON INSTALLATION NOTE Remove the package and screw out the nut Make the button through the tank cover as shown Be noted that the button shall be kept level Arrange big and small flush buttons according to the...

Page 8: ...189T HC K 23188T HC K 23189T HC For K 23188T ITHC K 23189T ITHC K 23188T ITHC K 23189T ITHC Fill Valve Fill Valve Flush Valve Flush Valve Push Button Push Button Continuous Clean Assy Float Canister Float Canister Button Box Button Box Fig 23 23 Fig 25 25 Fig 24 24 Steel Wire Steel Wire QUICK REMOVAL AND INSTALLATION For Quick Removal Turn off water supply Squeeze downward the blue part on the fil...

Page 9: ...ve time to fill 5 There is excessive noise when the tank is filling 3 The fill valve turns on off by itself without the toilet being flushed or it runs allowing water to enter the tank A Reconnect the chain to the trip lever or flush valve B Adjust the chain assembly to remove excessive slack A Fully open the water supply shut off valve B Clean the valve inlet valve head or supply line Flush the l...

Page 10: ...hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of corrosive cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage CAUTION Don t use any cement while installing the toilet WARNING Risk of product da...