TO INSTALL BOWL

Position the template and align with
drain hole.

Mark down the position of foot and 5
holes.

Drill holes on ground with the drill of
10mm (3/8"), then insert anchor to
holes.

CAUTION:

Please make sure there is

no water pipe or spool under the 5
holes to be drilled.

Fig.#7

7

Firmly press the toilet gasket onto the
toilet outlet of plastic trap.

Wax ring type toilet gasket

should not be installed at temperatures
less than 21 C.

If you are using a toilet

gasket with an integral plastic sleeve,
make sure the gasket is positioned
with the sleeve facing away from the
toilet.

NOTE 1:

NOTE 2:

o

1

21

2

o

C

Install brackets.

Plastic Trap Outlet

Toilet Gasket

Fig.#8

8

Install plastic to ground and mounted
with 3 set of bolts

firmly.

(not supplied)

3

(

)

NOTE:

Must use the toilet installation

gasket ring (not supplied) to seal the
area where the waste pipe contacts
the construction section to avoid
leakage.

(

)

Fig.#4

4

Fig.#5

5

Drain Hole

3/8

10mm

Fig.#6

6

1391134-T01-A

Summary of Contents for REACH K-3983T-HC

Page 1: ...305mm K 3983T HC 3 3 4 8 400mm K 4012T HC NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm centers Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing in dimension Closet flange must be 305 400mm on center from wall Carefully inspect the new fixture for any sign of damage For new construction...

Page 2: ...tank install one before installing the new toilet NOTICE 254mm 305mm 8mm T 2 10mm Unit mm Reference Value K 3983T HC FRONT OF BOWL OF OUTLET C L 305 Finished Wall Supply 366 724 361 394 200 160 722 340 275 WARNING Risk of personal injury or product damage WARNING Risk of external leakage Handle vitreous china products very carefully Vitreous china can break and chip if you overtighten bolts and nu...

Page 3: ...use white cement or high lime content cements to install this toilet The expansion of cement due to a rise in temperature may make the toilet crack or cause damage Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange mm 67mm 200mm 160 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the finished floor li...

Page 4: ... gasket should not be installed at temperatures less than 21 C If you are using a toilet gasket with an integral plastic sleeve make sure the gasket is positioned with the sleeve facing away from the toilet NOTE 1 NOTE 2 o 1 21 2 o C Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Install plastic to ground and mounted with 3 set of bolts firmly not supplied 3 NOTE Must use the toilet in...

Page 5: ...l valve Be sure the rigid connection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 12 12 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and ru...

Page 6: ...LATION NOTE Remove the package and screw out the nut Make the button through the tank cover as shown Be noted that the button shall be kept level Arrange big and small flush buttons according to the label of water consumption on the tank Tighten the nut from beneath the tank cover Fig 15 15 Fig 13 13 Install the tank lid and the seat Tighten the seat power line and pipe with mounting twist tie Per...

Page 7: ... debris or replace the piston seat washer assembly D Remove the tank and tighten the flush valve nut if flush valve gasket is leaking Do not overtighten If leakage continues replace the gasket E Adjust the tank water level if it is too high 2 No Flush IMPORTANT Use only genuine Kohler parts as shown to avoid property damage 4 Tank takes excessive time to fill 5 There is excessive noise when the ta...

Page 8: ...an seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage Please do not use hard materials like scouring pad to clean product surface especially the product logo CAU...

Reviews: