background image

3. Install the rectangular shield in the block screen of the tank,

and tighten the screw to fix the rectangular shield to the
tank.

3.

4. Fix the leak-proof gasket to syphon as shown in illustration,

and adjust the syphon to appropriate position to be fixed to
the infall of squat.

4.

5. When finishing the brickwork, eliminate unwanted part of

the rectangular shield.

5.

Rectangular Shield

Leak-proof Gasket

Syphon

Sharp Knife

Screw

Rectangular Shield

-12-

Block Shield

1048671-T01-K

Summary of Contents for RATIO K-6283T

Page 1: ...elated to installation with spares not provided by Kohler Water temperature must not exceed 27 C o 27 o C K 6283T 100 K 6284T K 6285T Ordering Information RATIO In Wall Tank Faceplate K 6283T HYDRO TOWER 100 In Wall Tank With Frame K 6284T ODEON In Wall Tank Without Iron Rack K 6285T K 6284T 3 6L K 6285T 7 7 0 2L Function Explanation Anti flow backwards Adjustment of inlet water level Adjustment o...

Page 2: ...75 348 850 196 15 55 25 OK FFB 400kg 400 Advantages Of In wall Tank Sustainable to pressure of 400 kg Will not affect the structure of the wall and provides excellent sound insulation Easy installation and time efficient Clean garbage free and space Madeofmacromolecularmaterialsthatpreventscorrison andleaking Adjustabledualflushdesignwhichconserveswater Donotneedtoprepareanyotherspareparts Easymai...

Page 3: ...INSTALLATION Ways of Installation There are two ways of installation for the products In wall tank toilet and In wall tank squat In wall Tank Squat 3 In wall Tank Toilet 1048671 T01 K ...

Page 4: ... frame screw with nut then tighten the frame screws on the fixing frame with medium Allen key as shown in illustration A 2 Drill four holes with diameter of 10mm and depth of 70mm with churn drilling as shown and fill in the holes with bulge screw knock in with hammer if necessary and tighten the screw A 1 B A 2 10mm 70mm 4 O Tank Frame Nut Adjustable Bracket Medium Allen Key A B Expanding Bolt Ga...

Page 5: ... with spanner Ensure the tank to remain level 4 Fix the drainage cap on the fixing bracket as shown in the illustration Tighten the screws with medium allen key and install the drainage cap on the drainage hole 4 3 A B Level Hexagonal screw Screw Medium Allen Key Adjustable Bracket Screw Loosen Spanner Tighten A B 5 Fixing Bracket Drainage Cap Screw Medium Allen Key Drainage Hole 1048671 T01 K ...

Page 6: ...d tighten the screw to fix the rectangular shield to the tank 6 7 Tighten the long screw into the holes of tank bracket and cover the drainage cap with big filtration cap and the drainage hole with small filtration cap 7 Rectangular Shield Screw Block Screen 6 Connecting Pipe Water Pipe Drainage Hole Drainage Cap Big Filtration Cap Small Filtration Cap Long Screw Tank Bracket 1048671 T01 K ...

Page 7: ...e back side of the tank with a ruler and a pencil and reserve appropriate space according to the distance from the back of the tank to the outlet hole on the wall 9 10 Eliminate unwanted part of the pipe and outlet pipe according to the marks of reserved space and rasp a smooth surface with files inlet 10 Rectangular Shield Big Filtration Cap Small Filtration Cap Inlet Pipe Outlet ipe P Inlet Pipe...

Page 8: ...d outside the wall as shown in the illustration If the long screw outside the wall is not long enough or much longer than that needed it should be adjusted with screwdriver or by hand Then apply lubricant to drainage pipe and limber pipe to ensure a smooth installation 12 48mm 58mm 13 Install the Toilet as shown in the illustration and use a spirit level to ensure the lavatory to remain level 13 L...

Page 9: ...N Remark Stir pole shall remain level 15 OPEN Long Screw Rubber Cover Hexagonal Nut Decoration Cap Gasket Block Screen Locknut Adjustable Board Stir Pole 9 14 Install the rubber cover gasket hexagonal nut and decoration cap onto long screw according to the order shown in the illustration 1045164 Screw Cover 1048671 T01 K ...

Page 10: ...s in installation 16 LOCK 17 Install the cover as shown in the illustration Put the lock on the cover directly on the reversed lock on adjustable board then push the cover and lock it The installation shall begin from bottom to top 17 18 In wall tank toilet is ready to be put into use 18 Lock Adjustable Board Reversed Lock Cover Adjustable Board Locknut Long Flush Button Short Flush Button 10 Fini...

Page 11: ...Ensure the fixing bracket to remain level B 1 12mm 70 76mm Screw 11 O Fixing Bracket Bulge Screw Gasket Spring Nut Put the tank onto the fixing bracket as shown in the right figure and adjust the tank to level Then tighten screws with hex head key Note it is a must to keep the tank level Connect the inlet hose with tank inlet pipe Note it is necessary to keep the inlet valve closed at this step Le...

Page 12: ...ix the leak proof gasket to syphon as shown in illustration and adjust the syphon to appropriate position to be fixed to the infall of squat 4 5 When finishing the brickwork eliminate unwanted part of the rectangular shield 5 Rectangular Shield Leak proof Gasket Syphon Sharp Knife Screw Rectangular Shield 12 Block Shield 1048671 T01 K ...

Page 13: ...e adjustable board to block shield the locknut should be put directly on positong of the sign of OPEN Remark Stir pole shall remain level 6 OPEN Lock Adjustable Board Reversed Lock Cover Adjustable Board Locknut Stir Pole Block Shield Locknut Adjustable Board 8 Install the cover as shown in the illustration Put the lock on the cover directly on the reversed lock on adjustable board then push the c...

Page 14: ...se A Hold the cover with both hands and push upward to take down the cover A 9 Long Flush Button Short Flush Button MAINTENANCE AND CONTROL PROCEDURES MAINTENANCE AND CONTROL PROCEDURES Finished Installation Illustration Cover Cover 14 1048671 T01 K ...

Page 15: ...en with screwdriver to take out the block screen C Block Screen D Wash Filtration Net Close corner valve first then loosen and take out the tighten nut and wash the waste on filtration net with clean water Then reset the tighten nut to the original position D Open Close Corner Valve Tighten Nut Filtration Net Loosen Nut 15 1048671 T01 K ...

Page 16: ...lustration Then take out the fixing frame with both hands Pole Control Button Fixing Frame F Pull out reversed lock on the fixing frame as shown in the illustration and adjust the height of the control poles to ensure the leak proof of drainage valve F 16 Fixing Frame Fixing Frame Control Button Pole 1048671 T01 K ...

Page 17: ...rease the water level in the tank H G Adjust Drainage Valve Drainage volume and overflow level of the tank can be adjusted by drainage valve 1 Heavy drainage adjustment Open adjustment switch to open the small hole 2 Slight drainage adjustment adjust the height of floating box and the water level of slight drainage will be at the bottom of the floating box G 1 2 Control Pole Drainage Valve Adjustm...

Page 18: ...rol pole is too long Adjust the control pole to appropriate position Water level of the inlet valve is not appropriate No drainage when pressing the heavy and slight drainage button Too high or too low water level Leak of the toilet and squat Symptoms Probable Causes Recommended Action Control pole is too short Inappropriate adjustment of the overflow pipe Toilet swing Hexagonal nut is loose 15 9 ...

Reviews: