17
1057616-W2-J
Rada 215 dk, 215-t3 dk, 222 dk,
222-t3 dk and 215-t3 oem
The mixing valve is supported by the inlet and
outlet pipework only, which must be suitably and
securely fastened.
Inlets and outlet are external BSP union, intended
to accept flat-faced connectors (see note). It is
recommended that such union connections are
used, so that the mixing valve body can be readily
removed from its pipework for maintenance
purposes.
Note!
Flat faced connectors are
not
supplied with
215-t3 oem, 215 dk or 222 dk models.
1.
Three additional connectors (see note above)
are supplied (2 elbows, 1 straight, terminating
in compression connections), which are
interchangeable to the inlets and outlet.
Select the most appropriate configuration for
the intended installation, and, with the nylon
washers in place, secure to the mixing valve
body.
2.
Fit and secure the supply pipework.
3. Important!
Flush through the hot and cold
supplies thoroughly before connection to
mixing valve.
4.
Connect the inlet and outlet pipework to the
valve.
Note!
Make sure that the hot and cold supplies
have been connected to the correct inlets, and
that all connections are watertight.
5.
Refer to section:
‘Commissioning’
.
Rada 215-t3 zc
Note!
Rada offset connectors and offset pipe
concealing plates are not supplied with this mixing
valve, but are available separately as optional
accessories.
1.
Check that the hot and cold supplies are piped
to the correct inlet positions. Supplies (pipe
centres between 128-178 mm) must terminate
in 1/2" BSP internal sockets to within 3 mm,
above or below, the final wall surface.
Note!
It is essential that inlet supply sockets
are parallel, and square with wall surface.
2.
Join offset connectors and screw into sockets
so that faced edge is 34 mm proud of
final
wall
surface (refer to illustration). Shorten 1/2" BSP
external thread, if necessary.
34 mm
3/4" Union
Thread
1/2" Thread
(shorten if necessary)
3.
Screw pipe concealing plates onto offset
connectors.
4. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer.
Failure to do so may result in product
malfunction and will not be covered under the
guarantee.
5.
With the nylon washers in position, offer up the
mixing valve and tighten the union nuts onto
the offset connectors.
6.
Connect the outlet pipework:
6.1
for 15 mm compression pipework outlet
connection: fit the compression nut and
olive (refer to illustration).
6.2
for 1/2" BSP union outlet connection: fit
flat-faced insert, press in firmly (refer to
illustration).