![Kohler ODEON K-6286T Installation Instructions Manual Download Page 3](http://html1.mh-extra.com/html/kohler/odeon-k-6286t/odeon-k-6286t_installation-instructions-manual_1990097003.webp)
-3-
1. Mark on the wall for appropriate position for fixing bracket,
and drill four holes with diameter of 12mm and depth of
70-76mm with churn drilling as shown in illustration, and fill
in the holes with bulge screw and tighten the screw to set
the fixing bracket.
Note: Ensure the fixing bracket to remain level.
1.
12mm
70-76mm
Screw
O
Fixing Bracket
Bulge Screw
Gasket
Spring
Nut
Put the tank onto the fixing bracket as shown in the right
figure and adjust the tank to level . Then tighten screws with
hex-head key. Note: it is a must to keep the tank level.
Connect the inlet hose with tank inlet pipe. (Note: it is
necessary to keep the inlet valve closed at this step.)
(
)
Level
Tank
Tighten
Loosen
Medium Allen Key
Connecting Pipe
Water Pipe
INSTALLATION
1206284-T01-A