background image

7

1292000-W2-B

5.

  Make sure that the slots in the slide 

bar are aligned with the lugs in the 

support  and  fit  the  two  slide  bar 

supports  to  the  ends  of  the  slide 

bar. Make sure that each support is 

pushed firmly home.

 Note!

  If  replacing  an  existing  Mira 

Slide Bar proceed to instruction 8.

6.

  Using  the  assembled  slide  bar  and 

supports  as  a  template,  mark  the 

position of the two fixing holes using 

the centre slot.

 Warning!

  Make  sure  that  there  are 

no buried cables or pipes in the wall 

before drilling.

7.

  Drill  the  two  7  mm  holes  for  the 

fixing  screws  and  insert  the  wall 

plugs  supplied.  (Alternatively  use 

proprietary cavity fixings for dry lined, 

stud  partition,  shower  cubicle  or 

laminated panel walls).

8.

  Fix the bottom slide bar support to the 

wall using the screw provided. Make 

sure that the screw is fully tightened.

9.

  Loosely  screw  the  top  slide  bar 

support to the wall. Press firmly down 

on the top slide bar support and, while 

continuing to apply force, fully tighten 

the screw. 

10.

  Fit  the  end  caps  to  the  slide  bar 

supports.

11.

  Check  the  slide  bar  cannot  be 

rotated  or  vertically  moved.  If  there 

is  movement  remove  the  slide  bar 

assembly  from  the  wall.  Check  the 

slide bar support lugs are properly 

engaged with the slots in the slide bar 

and the supports are pushed fully onto 

the slide bar ends. Refit the slide bar 

assembly.

12.

  Refer to sections:

 Handset Installation

 

to  complete  the  fittings  installation.

End Cap

End Cap

Top Slide Bar 

Support

Slide Bar

Clamp 

Bracket 

Assembly

Wall Plug

Fixing Screw

Hose 

Retaining 

Ring

Slide Bar 

Support Lug

Bottom Slide Bar 

Support

Summary of Contents for Mira Logic

Page 1: ...ructions must be left with the user Mira Logic Shower Fittings Adjustable Range If you experience any difficulty with the installation or operation of your new shower fittings then please refer to Fault Diagnosis before contacting Kohler Mira Limited ...

Page 2: ...afe manner in accordance with current local authority recycling or waste disposal policy Important Safety Information This Installation and User Guide covers the following products Mira Logic Exposed Variable Shower Fittings ev An adjustable spray handset with four different spray actions supplied complete with flexible hose clamp bracket assembly slide bar supports and hose retaining ring gel hol...

Page 3: ...ssembly 1 x Hose Retaining Ring 2 x Fixing Screws 2 x Wall Plugs 1 x 1 25m Flexible Hose 1 x Slide Bar 2 x Hose Seals 1 x Applicator Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included Mira Logic ev and biv Shower Fittings Pack Contents ...

Page 4: ...Seal 1 x Backplate 2 x Wall Plugs 2 x Backplate Screws 1 x Olive 1 x Olive Nut Mira Logic biv Shower Right Angle Connector Fittings Pack Mira Logic ev and biv Shower Fittings 344 mm Max 659 mm Dimensions 1 x Hexagonal Wrench 1 x Screw ...

Page 5: ... dropping below the spill over level of the bath or shower tray This will prevent water supply contamination due to backsiphonage 2 Installations must comply with UK Water Regulations Bye laws Scotland and Building and Plumbing Regulations in force at the time of installation 3 When installing the shower fittings in a cubicle position with the spray pointing across rather than toward the opening o...

Page 6: ...on a suitable position for the slide bar avoiding buried cables and pipes Make sure that when the hose retaining ring is placed on the lowest position on the slide bar there is a minimum of 25 mm between the handset and bath tray spill over level This is necessary to prevent back siphonage 2 Important The slide bar has been supplied with an applicator fitted to one end refer to illustration to ass...

Page 7: ...ated panel walls 8 Fix the bottom slide bar support to the wall using the screw provided Make sure that the screw is fully tightened 9 Loosely screw the top slide bar support to the wall Press firmly down on the top slide bar support and while continuing to apply force fully tighten the screw 10 Fit the end caps to the slide bar supports 11 Check the slide bar cannot be rotated or vertically moved...

Page 8: ...r control Make sure that the hose washer is fitted 2 Pass the flexible hose through the hose retaining ring and screw the remaining end of the hose onto the handset Make sure that the hose washer is fitted 3 Place the handset in the clamp bracket assembly Handset Hose Washer Clamp Bracket Assembly Hose Retaining Ring ...

Page 9: ...m the pipework back to the required depth from the finished wall surface Remove all burrs and sharp edges Installation of the Right Angle Connector 3 Drill the fixing holes 7 mm diameter for screws supplied DO NOT drill through the backplate into the wall DO NOT drill into buried cables or pipes 29 33 mm 90 1 2 ...

Page 10: ...work to clear all debris Install the O ring over the pipe Fit the cover and twist to lock Secure the backplate to the wall so the foam seal is fully compressed 5 Fit the pipe collar and lock Re check the pipe length 29 33 mm foam seal ...

Page 11: ...11 1292000 W2 B Check for leaks 8 9 Tighten the screw using the 3 mm hex key supplied to lock the assembly Fit a shower hose with a 15 mm rubber washer 10 ...

Page 12: ...Mode 4 First second and third row ON Clamp Bracket Adjustment ev and biv shower fittings only 1 Depress the release button and slide the clamp bracket assembly to the required position 2 Move the handset to the required angle Afriction mechanism within the clamp bracket assembly will hold the handset at the desired angle Release Button Clamp Bracket Assembly ...

Page 13: ...n over a few minutes Problem with shower control This is quite normal Changing the angle of the shower fitting may vary the draining time Refer to the shower control Installation and User Guide Shower temperature changes when spray action is adjusted Adjusting the spray action changes the flow of water This may affect some shower controls and plumbing installations To minimise the effect make sure...

Page 14: ...BSM 450 30 Hose Retaining Ring Chrome 1867 045 Adjustable Handset Assembly Chrome 450 17 Slide Bar Wall Fixing Pack Components Identified A 1844 166 RAC Connector Mounting Pack 450 24 Clamp Bracket Assembly Chrome 450 27 Slide Bar Support Assembly Components Identified B A A B B 450 28 Slide Bar Chrome 1844 165 RAC Connector Shroud Chrome ...

Page 15: ...15 1292000 W2 B Notes ...

Page 16: ...n for loss of use of the product or consequential or indirect loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replacement parts to repaired or modified by persons not authorised by comply with the requirements of the TMV2 or repaired or modified by persons not authorised by TMV3 ...