background image

18

1285246-W2-D

Fit One Flow Regulator Per Outlet!

We highly recommend the fitting of a flow regulator for optimum temperature control and 

showering experience.

For maintained (running) water pressure greater than 0.5 bar, installing a flow regulator can 

help to reduce:

•  Excessive shower force

• 

Noise due to high or unequal water pressure

•  Unstable supply temperature

•  Cooler outlet temperatures due to the colder seasons

12 L/min (red)

 to reduce excessive shower force and stabilise temperatures.

6 L/min (black)

 for eco water conservation while showering.

Note:

 In some circumstances such as when the incoming cold water temperature supply is 

very low to a combination boiler a 9 l/min flow regulator may be required to improve the hot 

water performance. Contact Mira Customer Service.

Note: 

The 6 l/min flow regulator may affect the performance of some combination boilers 

while the shower is running. Check with the boiler’s manufacturer before fitting.

DO NOT

 fit a flow regulator if the maintained (running) water pressure is less than 0.5 bar or 

the shower force is too low.

14

Information on Flow Regulators

Shower Spray

Handset*

Washer

Hose

*Subject to the fitting’s ability to accept the flow regulator. 

Note: For the S valves, fit 

the 12 l/min flow regulator 

or 6 l/min flow regulator 

into the handset as shown.

Note: For the ERD or Store products the 

12 l/min flow regulator is pre fitted. For low 

pressure systems, if more flow is required, 

remove the flow regulator as shown.

Summary of Contents for Mira Agile ERD+

Page 1: ...Mira Agile S Mira Agile ERD Mira Agile Sense ERD Mira Agile Store EV Mira Agile EV These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS please call u...

Page 2: ...as reached the end of its serviceable life please take it to a recognised facility such as your local civic amenity site for recycling Your local authority or retailer will be able to advise you of yo...

Page 3: ...672 257 2 710 194 DE FR GB IT NL SE USA 8 167 215 8 517 282 Pack Contents 2 x Screws 2 x Wall Plugs 2 x Flow Reg 2 x Hex Key 1 x Grease Sachet 1 x Shower Unit Agile S Agile S Eco Agile EV 1 x Wallplat...

Page 4: ...x Guarantee Card Documents 1 x Shower Unit 1 x Wallplate Pack 2 x Screws 2 x Wall Plugs 2 x Hex Key 1 x Grease Sachet 2 x Grubscrew 1 as a spare 1 x Component Pack 1 x First Fix Pipe Guide Agile ERD...

Page 5: ...E OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY INSTALLING THE SHOWER 1 Installation of the shower must be carried out in accordance with these instructions by qualified competent personnel Read...

Page 6: ...ce to the shower unit without supervision 10 Always check the water temperature is safe before entering the shower 11 DO NOT adjust the temperature control rapidly while using the shower 12 Use cautio...

Page 7: ...he maximum hot water temperature is limited to 65 C Cold Water Range up to 25 C Minimum Recommended Differential between Hot Supply and Outlet Temperature 12 C Thermostatic Shut down For safety and co...

Page 8: ...to a build up of static pressure 5 DO NOT apply excessive force to plumbing connections always provide mechanical support when making plumbing connections Any soldered joints should be made before con...

Page 9: ...pressure for the appliance and must not be fitted For Fluid Category 5 double checkvalves are not suitable 12 The position of the shower and shower fittings must provide a minimum air gap of 25mm bet...

Page 10: ...the boundaries listed step 6 below the wall plate may not conceal drilled holes The shower fittings should be positioned at a convenient height for all the family Position the fittings to spray acros...

Page 11: ...onnection to the valve DO NOT use any other pipe sizes 4 Ensure you have enough pipework through the wall to allow it to be cut to the specified length when wall is finished refer to the instruction o...

Page 12: ...O NOT drill through the pipe guide Mark these two Holes First Fix Pipe Guide b Make sure the holes drilled through the noggin are square and level to the mounting surface SIDE VIEW TOP VIEW 50 mm Min...

Page 13: ...es may damage the seals in the mixer valve Note De burr the pipework if necessary IMPORTANT Use 15 mm copper pipe to valve Min 18 mm to Max 28 mm from finished wall surface Plasterboard 1 5 m m 1 5 m...

Page 14: ...ugh them into the finished wall surface Drill through the 2x holes in the shroud 3 4 Pipe Shroud Drill holes here 6 mm Wall Plug Fit the wallplate over the pipes ensuring they do not push back into th...

Page 15: ...revent the possibility of property water damage the screws MUST be tightened YOU MUST FULLY TIGHTEN the pipe retaining screws to clamp the pipes Failure to do so may result in water damage to your pro...

Page 16: ...hexagonal wrench Tighten securely Retaining Screw Retaining Screw 11 12 Backplate Retaining Screw Orientation markers always on top DO NOT USE POWER TOOLS TO TIGHTEN THE RETAINING SCREW Grease the pip...

Page 17: ...water supplies and check for leaks Refer to separate guide for instructions on how to fit the shower fittings Note The shower must be commissioned before first use see section Commissioning and Inform...

Page 18: ...s very low to a combination boiler a 9 l min flow regulator may be required to improve the hot water performance Contact Mira Customer Service Note The 6 l min flow regulator may affect the performanc...

Page 19: ...rty of the homeowner Note For Type 2 installations the maximum temperature is determined by application refer to the TMV2 Requirements Manual If you experience any difficulty with the operation of you...

Page 20: ...approximately 1 C Warmer Cooler 3 5 4 Turn the shower off again Refit the control lever Red Stopper Handle Drive Ensuring correct orientation OFF at the top refit the stop assembly and the retaining...

Page 21: ...use a single sequential control for on off and temperature control Allow a few seconds for any temperature adjustment to take effect Allow temperature to stabilise before making a new adjustment Alwa...

Page 22: ...stop assembly and the retaining screw to the body 2 1 User Maintenance WARNING PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE DO NOT allow children to clean or perform any...

Page 23: ...Important The showerhead must be descaled regularly Keeping the shower spray clean and free from limescale will ensure that your shower continues to give the best performance In service Tests The prin...

Page 24: ...Service Fluctuating or reduced flow rate Hose shower head or filter blocked Remove and clean Check hose and replace if necessary Check the filters for any blockage See User Maintenance The inlet press...

Page 25: ...2 Wall Plate Assembly Agile S Agile S Eco Agile EV 1736 950 Cartridge Assembly 1736 986 Screw Pack A 1736 949 Control Assembly 1736 980 Backplate 1736 706 Outlet Nipple A A A 1736 990 Pipe Guide 1736...

Page 26: ...36 962 Wall Plate Assembly Agile ERD Agile Sense ERD Agile Store EV 1736 950 Cartridge Assembly 1736 986 Screw Pack A 1736 949 Control Assembly 1736 980 Backplate A 1736 990 Pipe Guide 1736 984 Headnu...

Page 27: ...27 1285246 W2 D Notes...

Page 28: ...for loss of use of the product or consequential or indirect loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed represent...

Reviews: