Assemble the bolt cap bases, washer,
and nuts on the exposed T-bolts.

H

andtighten the nuts, then tighten

them an additional 1/2-turn.

Overtightening may cause
breakage or chipping of the
vitreous china.

If the T-bolts extend more than 6mm
(1/4") over the top of the nuts, cut off
the excess and file the end. Wipe
away any residue. Install the bolt cap.

CAUTION: Risk of personal
injury or product damage.

T

T

6mm

Fig.#6

6

T-Bolt
T

Bolt Cap*

Nut

Washer

Bolt Cap Base*

TO INSTALL NEW TANK

Make sure the three tank bolts extend
completely through the holes in the
gasket. Set the tank onto the bowl,
using the tank bolts as a guide. Center
the gasket on the inlet of the bowl.
Assemble the washer and brass nuts
onto the bolts.

Alternately tighten the three brass nuts
so the top of the tank and the top of
the bowl are both level. Be sure the
brass nuts are tight enough to achieve
a wate tight seal.

Over tightening may cause
breakage or chipping of the
vitreous china.

CAUTION: Risk of personal
injury or product damage.

Fig.#7

7

Brass Nut

Washer

Gasket*

*

Tank Bolt

* Shape of the actual gasket may not be the
same as shown, but installation method
remains the same.
*

Supply Shank*

Supply Shut-Off Valve

Fig.#8

8

*

(

)

(

)

TO CONNECT WATER
SUPPLY

* Flexible hose (not provided) are
recommended to connect the supply
line to the fill valve. If you use a rigid
connection(not provided), take care
not to apply side forces to the bottom
of the fill valve. Be sure the rigid
connection must be fit with supply line
completely to prevent damage shank
by forced connection.

If you temporarily plugged the closet
flange with a rag, remove the rag at
this time and ensure that the drain pipe
is clear and free of debris.

Carefully align and lower the

over

the closet flange and T-bolts. Apply full
body weight to the

rim to set the

seal.

Do not lift or rock the

after placement - a new

toilet gasket must be installed if
you break the watertight seal.

bowl

bowl

bowl

CAUTION: Risk of external
leakage.

1033003-T01-N

Summary of Contents for MEMOIRS K-3429T

Page 1: ...454T MEMOIRS Classic Toilet K 3429T C Includes Elongated Bowl K 4254T Tank K 4454T French Curve Quite close Seat K 4713T MEMOIRS Stately Toilet K 3439T Includes Elongated Bowl K 4254T Tank K 4464T MEMOIRS Stately Toilet K 3439T C Includes Elongated Bowl K 4254T Tank K 4464T French Curve Quite close Seat K 4713T MEMOIRS Stately Toilet K 3439T S Includes Elongated Bowl K 4254T Tank K 4464T French Cu...

Page 2: ...serve all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm 5 1 2 centers 51mm 2 passageway Water depth from the rim Ensure that the new drain has the correct roughing in dimension Carefully inspect the new fixture for any sign of damage For new construction refer to the dimensions in for locating the shut off valve Fixture dimensions are nominal and conform ...

Page 3: ...use of cement NOTICE 8mm T Fig 3 3 Closet Flange T bolts T Fig 4 4 Supply Shut Off Valve Closet Flange Centerline 127mm 305mm 127mm Remove the old gasket from the floor and the closet flange with a putty knife Remove the old T bolts and discard them If the new toilet is not installed immediately temporarily stuff a rag into the closet flange NOTICE TO INSTALL SUPPLY SHUT OFF VALVE Install the supp...

Page 4: ... seal Over tightening may cause breakage or chipping of the vitreous china CAUTION Risk of personal injury or product damage Fig 7 7 Brass Nut Washer Gasket Tank Bolt Shape of the actual gasket may not be the same as shown but installation method remains the same Supply Shank Supply Shut Off Valve Fig 8 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line...

Page 5: ...T WITH BALLAST Test flush the toilet Periodically check all connections for leaks for several days following installation Set the tank cover in place on the tank Fig 10 10 Float Fill Valve Cap OPEN MINOR ADJUSTMENT OF WATER LEVEL Move the snap along OPEN direction To lower water level Move water cup down to a proper height and rotate screw anticlockwise to achieve the desired water level Refer to ...

Page 6: ... of Water Level for waterline adjustment 3 Incorrect water level height A Valve float cup does not contain enough water to provide required ballast B Float height incorrect A During fill cycle hold float under water a few seconds to allow it to fill with water ballast B Refer to Minor Adjustment of Water Level for waterline adjustment 4 Long or noisy tank fill cycle A Plugged valve inlet or supply...

Page 7: ... 7 3 A B A B 6 A B A B 7 A A 5 A B C D E A B C D E 1 A B C A B C 2 A B C D A C D B 4 A A 2A 1033003 T01 N ...

Page 8: ... in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 8 CAUTION Don t use any cement while installing the toilet WARNING Risk of product damage Heat expansion of the toilet may damage the f...

Reviews: