OVERFLOW STATUS
NOTE:
1
1
1
Water level reaches overflow level.
The electronic drain automatically opens. Overflow animation is displayed and sound alarm starts.
Turn off the tap. When water level is below overflow level, the electronic drain automatically closes. Sound
alarm stops. Overflow level is 400mm.
When the bath reaches overflow level, water level may rise quickly if you enter the bath, which
may trigger the compelling drain function. Compelling drain function will discharge lots of water, so it is
not recommended to use the bath when it reaches overflow level.
STOPPING THE BATH
1
1
1
Long press "
" to stop massage.
Carefully exit the bath.
Press the electronic drain on/off button "
". Drain animation is displayed.
POWER OFF STATUS
NOTE:
1
1
The electronic drain automatically starts under power off status.
Please do not use the bath in case of outage. In this case, the electronic drain automatically opens and
the bath can not be filled with water.
Plug again, and the electronic drain is at draining status.
PIPE CLEANING OPERATION
1
1
1
1
1
1
Press the purge button "
" and pipe cleaning animation is displayed.
The bath automatically drains.
After the bath is drained, the electronic drain is off and the bath will be filled automatically.
The bath fills until water reaches the water level for automatic cleaning.
The pump automatically runs for two minutes.
Electronic drain opens. The bath automatically drains and pipe cleaning is finished.
COMPELLING DRAIN FUNCTION
1
If the overflow level sensor does not work, you can use the compelling drain function to prevent water
overflow to your bathroom. Automatic drain water level is 430mm.
9
1276616-T01-A
Troubleshooting Chart
SYMPTOMS
PROBABLE CAUSES
RECORRECTIVE ACTION
1. Massage does not start.
A. Controller is not power on.
2. Pump stops automatically
within 20 minutes.
B. User keypad cable loose or damaged.
C. User keypad does not work.
D. Pump does not work.
A. Set/reset GFCI or ELCB breaker;
check wiring.
B. Check wire connections. If necessary,
replace user keypad.
C. Replace user keypad.
D. Replace pump.
A. GFCI or ELCB trips.
A. Correct GFCI or ELCB trips.
A. Replace controller.
3. Pump does not stop
automatically after 20 minutes.
A. Controller trips.
Summary of Contents for KARESS Series
Page 11: ...1 1 1 1 QB 2585 2007 A B GFCI 11 1276616 T01 A ...
Page 13: ...A 2 mm B 80 390 2 1 1 1 1 1 13 1276616 T01 A ...
Page 14: ...B 1 1 1 1 A B C D E A 1 1 1 1 1 50 14 1276616 T01 A ...
Page 15: ...C GFCI 220 10 GFCI 1 1 D 1 1 1 1 1 1 1 1 1 350 E 15 1276616 T01 A F 1 ...
Page 16: ...H I 12mm 6mm 1800 12mm 900 600 1 A 350 16 1276616 T01 A G 1 1 1 ...
Page 17: ...1 1 1 1 1 1 1 350mm 1 1 1 1 1 1 L1 L2 L1 C 17 1276616 T01 A B ...