Install Plumbing
CAUTION : Risk of property and product damage.
Ensure a watertight seal on the bath drain connections.
Faucet Installations
NOTE:
Install the faucet valve according to the installation instructions included with the faucet.
Refer the faucet position according to illustrated.
Open the hot and cold water valves, and check the supply connections for leaks.
Drainage Installations
The bath drain has been installed onto the bath before it leaves factory.
When the bath is securely positioned, connect the flexible pipe to the drain trap.
Run water into the bath, and check the drain connections for leaks.
Apply silicon sealant between the flexible pipe and the outlet pipe.
Make Electrical Connection
DANGER : Risk of fire, electric shock, or injury to persons.
To
reduce
the
risk
of
electric
shock,
connect
the
pump
to
a
properly grounded Earth-Leakage Circuit-Breaker (ELCB), Ground-Fault Circuit-Interrupter
(GFCI), or Residual Current Device (RCD).
WARNING : Risk of fire, electric shock, or injury to persons.
When using electrical products, basic
precautions should always be followed, including the following:
The above units must be connected by a qualified electrician.
Handle
Spout
Diverter
Handshower
Outlet Pipe
Flexible
Pipe
Silicone
Finished Floor
1334405-EM2-A
6